background image

4. PLEASE READ THIS IMPORTANT SAFETY INFORMATION

Products manufactured by the MX Group are safe and without risk provided 
they are installed, used and maintained in good working order in accordance 
with our instructions and recommendations.

Layout and sizing of pipework MUST be such that when other services 
are used, pressures at the shower control inlets do not fall below the 
recommended minimum.

DO NOT choose a position where the shower could become frozen.

DO NOT connect this mixer valve to any form of tap or fitting not 
recommended by the manufacturer.

Conveniently situated service valves in each inlet supply MUST be fitted 
as an independent method of isolating the shower should maintenance or 
servicing be necessary, these valves SHOULD NOT restrict the flow.

DO NOT operate the shower outside the recommended temperatures and 
pressures stated in this guide.

Always test the water temperature with your hand before entering the 
shower.

NOTE: As a competent person installing this shower you should ensure 
that all users are very conversant in its operation.

The British Burns Association recommends 37˚C to 37.5˚C as a 
comfortable bathing temperature for children. In premises covered by the 
Care Standards Act 2000, the maximum mixed water outlet temperature is 
41˚C.

Metal surfaces on the hot supply may become hot during operation.

Arrange to have the mixer valve regularly serviced by a suitably qualified 
person.

The handset must be regularly cleaned to remove scale and debris.

!

!

!

!

!

!

!

!

!

!

!

!

Summary of Contents for Options Concentric Petite

Page 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Options Concentric Petite Thermostatic Mixer Valve with Riser Rail...

Page 2: ...uresystemsuptoamaximumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTA...

Page 3: ...components are included before starting the installation Description Quantity MixerValve 1 Handset 1 RiserRail 1 RiserRailFixing Brackets 2 HandsetHeightAdjuster 1 1 25mHose Washers 1 WallOutlet 1 Nu...

Page 4: ...dent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures...

Page 5: ...ar Thisshouldbeconfirmedbytheinstallation engineerorcompetentperson beforeinstallation WATER TEMPERATURE REQUIREMENTS Maximumhotwatertemperature 80 C Recommendedmaximum 65 C Minimumhotwatertemperature...

Page 6: ...saredsymbol nexttotheinletandmustbeonthelefthandside If themixervalveyouarefittingiswithariserrailthe outletshouldpointdown ifthemixervalveisforan overheadtheoutletshouldpointupwards n Themixervalveis...

Page 7: ...ngthepipework 3 Completethefittingofthepipeworkandthetiling leavingthepipeworkasshown about30mm outfromthefinishedsurface Fig3 4 Removethebackplatefromthemixervalveby removingtheretaininggrubscrews Pu...

Page 8: ...peworkandthetiling leavingthepipeworkasshown Thewallplate shouldbeattachedfirmlybetween60mmand 75mmbelowthefinishedsurface Removetheback platefromthemixervalvebyremovingtheretaining screws Puttheplate...

Page 9: ...henfitthe soapdish dampeningtherailwillmakeiteasierto slideon Finallyfitthehoseretainingringontothe bottomoftherailbelowthesoapdish Fig4 6 Replacetherailassemblyintothelowerbracket Refitthetopbracket...

Page 10: ...ets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly...

Page 11: ...evalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpres...

Page 12: ...thecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe productandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotcoveranyproduct...

Page 13: ...contactdetails andthepostcodewheretheunitisinstalled 2 TheMXGroupCustomerServiceDepartmentwill beabletotellyouwhetherthefaultcanbesimply rectifiedbytheprovisionofareplacementpart 17 SPAREPARTS Intheev...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either through non availability of materials...

Reviews: