8. FITTING THE MIXER VALVE
1. The supply pipework can be plumbed from above or
below but must finish at the suitable connections,
which should be at 150mm centers. An Easy Fit
Kit can be purchased to make installation easier
if required. Connect the 15mm pipework using
standard compression fittings (Fig 1).
It is recommended you leave enough adjustment
in the feed pipes to allow leveling and positioning of
the valve.
2. Screw the supplied domed cover onto the dogleg
fittings until tight to the wall. If required put a bead
of silicone sealant around the inside of the domed
cover to prevent moisture entering the wall. The
domed cover can be adjusted depending on the
length of exposed thread from the elbow (Fig 2).
NOTE: The valve will not work correctly if the feeds are
connected the wrong way round.
3. Offer the mixer valve to the fittings, making sure
the sealing washers are in place, screw the unions
onto the fittings. The mixer valve must be positioned
horizontally with the hot supply on the left hand side
of the outlet (Fig 3).
NOTE: Ensure that the water outlet, which connects to
the vertical rail, is on the top of the valve.
Spillover
level