6. IMPORTANT INSTALLATION INFORMATION
Before proceeding with the installation check all the
components in the component list are present.
WARNING!
The shower must not be positioned where
it will be subject to freezing conditions.
The mixer valve should be fitted only after all the
pipework has been installed.
DO NOT modify or use jointing compounds on any of
the pipe fittings. DO NOT solder fittings near the mixer
valve as heat can damage the valves seals. Always
flush the system prior to installing the valve.
Before installing, make sure the mixer valve is kept
in a clean place to prevent any debris getting into the
openings while fitting the pipework.
n
The mixer valve is suitable for installation on a solid
wall, a stud partition wall, dry lined wall or fixing to a
cubicle or panel.
n
The water pipes should be securely attached
within the wall or panel to support the mixer valve and
prevent movement or water noise after installation.
n
The mixer valve hot water inlet has a red symbol
next to the inlet and must be on the left hand side. If
the mixer valve you are fitting is with a riser rail the
outlet should point down, if the mixer valve is for an
overhead the outlet should point upwards.
n
The mixer valve is designed to work at the same
hot and cold water pressures. If this is not the case a
flow controller (disc with small holes) can be fitted to
the higher pressure supply to the valve. This is best
done by testing each one to find out which gives the
best results.
n
The mixer valve will be installed in such a position
that the maintenance of the TMV and its valves and
the commissioning and testing of the TMV can be
undertaken.
Before fitting the mixer valve flush out the pipework in
accordance with Water Regulations Advisory Service
(www.wras.co.uk).
7. SITING OF THE MIXER VALVE
Position the mixer valve so that all controls can be
comfortably reached whilst using the shower.
The height of the showerhead should suit all user’s
requirements. When suspended from the hose
retaining ring, the showerhead should be a minimum
of 25mm above the spillover level of the bath or
shower tray.
NOTE: Easily accessible suitable service valves
(complying with Water Regulations Advisory Service
www.wras.co.uk), MUST be fitted as close as practical
to the valve, on the hot and cold water supplies to the
shower as an independent means of isolating the
water supplies should maintenance or servicing be
necessary. These valves should not restrict the flow.
!
!
Height of
showerhead
to suit user’s
requirements
25mm
minimum
Outline of bath or
shower tray
Spillover
level