10. FITTING THE MIXER VALVE
(CONT.)
IMPORTANT: Ensure that you have read through section 7. IMPORTANT INSTALLATION INFORMATION before
starting to fit the mixer valve.
8. Pipes must be fitted from the
¾
BSP female outlets
of the mixer valve to the location at which you wish
to position the wall outlet or overhead.These pipes
must end in
½
female connection so the wall outlet
and overhead arm can be fitted.
9. Once the mixer valve and wall outlet are fitted,
prior to fitting the trim plate enusre all connections
are watertight. This can be done by reconnecting
the water supplies an check all connections. To
do this you must fit the diverter handle in the
correct position so that ‘off’ is at the bottom. After
pressuring the system and checking no leaks
are present turn the handle to all other positions,
checking each time that there is no leak. Return the
handle to its original position and remove.
10. The trim plate is fitted by pushing it onto the mixer
valve until flush with the tiles (Fig 5).
NOTE: Before assembling the valve controls identify
all the parts and check that both the red markings on
the control shaft of the thermostatic control are inline.
11. Fit the on/off knob onto the diverter (the top shaft
with the ‘off’ at the bottom), push fully onto the
shaft. Hold firmly in position and tighten the grub
screw with allen key supplied (Fig 6).
12. Fit the stop ring into the middle shaft assembly
with the notch at the bottom (Fig 7).
13. Fit the temperature control knob onto the lower
shaft with the override button at the top. Hold the
control knob firmly in position and tighten the grub
screw with the allen key provided.
NOTE: Test water temperture by turning the flow
control clockwise. Allow the water to stabilise, this
should be at approximatley 38
˚
C. Use a thermometer
to accurately measure this temperature. If the
temperature is not 38
˚
C you need to adjust
the stop ring so it is in the correct position (see
commissioning).
14. Fit chrome caps to the grub screw hole for square
style and fit control levers to circular style to
complete valve installation (Fig 8).
Round Style
7
6
5
Square Style
8