49
M1.3.TIG200PAC.NLFREN 21052019
FR
28
/
50
E201 SC-A0
Fig 11.1 MMA Sketch Map
3) Please connect earth clamp t welder’s “+” and torch connect to welder’s “-“before TIG operation( as
shown in Fig 11.2). No PC is permitted or else welding can not processed normally. Connect torch
control cable to according connector and choose the proper welding mode per workpiece material
and check if the Tungsten electrode is in match with panel’s Tungsten electrode parameters and
current parameters. When under AC welding mode, improper balance parameter may result in
abnormal welding operation.
Fig11.2 HF Arc Ignition or Lift-arc TIG Welding Sketch Map
4) If the distance between workpiece and welder is long and the secondary line (holder cable and
ground cable) are long, please choose cables with wide cross section so that to lower cable voltage
drop.
Please preset current according to electrode specification, and clamp the electrode well. Welding
can be started by short circuit arc ignition. Please refer to welding parameters in Table 4.2
Fig. 9.2 Schéma d’installation pour l’amorçage de l’arc HF ou soudage TIG lift-arc
4. Si la distance entre la pièce et le poste à souder est grande, et que la ligne secondaire (câble du porte-électrode et câble
de terre) est longue également, choisissez des câble avec une grande section, afin de réduire la baisse de tension dans les
câbles.
Sélectionnez un courant en fonction des spécification de l’électrode, et fixez bien l’électrode. Le soudage peut démarrer par
un amorçage de l’arc par court-circuit. Reportez-vous aux paramètres de soudage dans le tableau 8.2.
copyrighted
document
- all
rights
reserved
by
FBC