Before storing the heater, make sure it is perfectly cool and dry. Cover the unit with a plastic bag, put it 

in its packing box and store it in a dry, ventilated place. 

Before starting any maintenance task, shut down, unplug and let the heater cool down 

for at least 15 minutes. 
Do not attempt any electrical repair yourself. If the heater needs service or repair, 

contact a qualified technician. 
Do not use a faulty unit unless a qualified technician has inspected and repaired it. 
When cleaning, make sure that water does not enter the unit. 
Do not open the enclosure to clean the inner parts. Do not spray water into the heater. 
Never use solvents, gasoline, toluene and similar aggressive chemicals to clean the 

heater. 

The following checks BY QUALIFIED PERSONNEL ONLY are recommended before every 

seasonal use: 

 

Fuel Filters 

Clean fuel filters by unscrewing the filter tray (clockwise) Remove the filter cartridge and wash it with 

petrol or replace it if necessary. Check seal O-ring and replace it if necessary. Reassemble the tray 

(Fig.2).  The fuel filter installed on the gear  pump should be cleaned or replaced if necessary by 

unscrewing cap H (see Fig. 6) 

Fig. 2 

Extract the burner head

Fig.3

 

  Fig.3 

Whirl disc 

    

Clean the whirl disc (Fig.3) using a brush and then blow compressed air on it. To get good 

combustion the air flow openings in the whirl disc should be perfectly clean and free. 

Nozzle 

Filter tray 

M1.0.WD340.EN

Summary of Contents for BGO-100A-16-F

Page 1: ...Instruction Manual Diesel Kerosene Heater WD340 M1 0 WD340 EN Please read and keep for future reference...

Page 2: ...ranty or representation for any particular purposes The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warning...

Page 3: ...EN INCORRECTLY USED E G INDOORS WITHOUT ADEQUATE AIR CIRCULATION OR IF NOT PROPERLY WORKING CO POISONING MAY LEAD TO DEATH GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTION...

Page 4: ...et Weight kg 40 8 Length mm 1215 Width mm 580 Height mm 705 Tank Capacity l 69 Operating range h 7 Standard Accessories Fuel gauge yes Handle 1 Ambient thermostat built in Malfunction detection signal...

Page 5: ...of at least 25 cm kW equally distributed between floor and high level with a minimum of 250 cm BGO 100A 16 F Minimum Opening Size 2500 cm Only install the heater in normal upright position Do not pla...

Page 6: ...FF O position The post ventilation phase will cool down the combustion chamber for 90 seconds Unplug the unit when not used for a long time Never disconnect the heater from mains to stop it while in o...

Page 7: ...er into the heater Never use solvents gasoline toluene and similar aggressive chemicals to clean the heater The following checks BY QUALIFIED PERSONNEL ONLY are recommended before every seasonal use F...

Page 8: ...usted by qualified technicians only Tampering with the unit may be dangerous Remove pressure gauge cap P Connect a pressure gauge on the pressure measuring port on pump Start heater and read fuel pres...

Page 9: ...e setting pressure on fuel pump Fig 6 This setting adjustment can be necessary to prevent excessive smoke emission due to lack of Oxygen Fig 7 Electrical Inspect cables electrical parts and connection...

Page 10: ...ged Clean nozzle blowing compressed air replace if necessary Fuel viscosity increased at low temperature Mix Diesel with 10 20 kerosene Heater starts but combustion is not good Insufficient airflow in...

Reviews: