background image

1

Insert the wheel shaft J to the corresponding hole of feet pipe E

insert the cotter K to the 

corresponding holes; slide the plain washer I over the wheel shaft J put the wheel H to the two sides 

of shaft,

screw the nut G to fix the wheel on the shaft. 

2

Put the heater body on the feet pipe assembly, make sure the 4 holes of handle A point towards the 

corresponding 4 holes on the feet pipe respectively. 

3

Using the screw B ,spring washer C, plain washer D and nut F to fix the feet pipe assembly and 

handle to the tank. 

5. Installation Instructions

Position the heater on a flat, level, non-flammable, solid surface. 
The exhaust gases are very harmful for people and animals when released in a closed 

space without ventilation.   
Indirect-fired heaters while used in indoor installation, must be connected to an exhaust 

pipe to vent the products of combustion outside. To maintain an adequate Oxygen rate, a 

minimum of 80 m

3

/h airflow from outside must be ensured.   

Direct-fired heaters are intended for use in outdoor open areas or in indoor well 

ventilated areas. For indoor use, provide permanent ventilation openings of at least 25 

cm²/kW, equally distributed between floor and high level, with a minimum of 250 cm². 

BGO-100A-16-F 

Minimum Opening Size 

2500 

cm² 

Only install the heater in normal upright position.

Do not place the heater near walls, corners or low ceilings.

Do not place the heater below a socket outlet.

Do not place the heater on moving vehicles or where it can tip over.

Keep the heater away from flammable, combustible, explosive or corrosive materials.

Keep the heater away from curtains or similar materials that could block the air inlet and

outlet.

Never block or restrict the air inlet and outlet for any reason.

Keep the power cable away from heat sources, sharp edges, cutting and moving parts.

Do not expose directly to the weather or to excessive humidity.

Do not place the heater in the immediate surroundings of a bath, shower or swimming

pool.

Follow general and special fire safety regulations in force in all fields of applications. In

any case ensure the following minimum safety clearances from materials or objects in

the surroundings of the heater:

Side:

1 m 

Air inlet side:

1 m 

Top:

1.5 m 

Hot air outlet side:

3 m 

Floor:

0 m 

Floors and ceilings must be made of fireproof materials in the place where the heater is

operated.

Do not connect direct-fired heaters to air ducts.

6. Instructions for Use

M1.0.WD340.EN

Summary of Contents for BGO-100A-16-F

Page 1: ...Instruction Manual Diesel Kerosene Heater WD340 M1 0 WD340 EN Please read and keep for future reference...

Page 2: ...ranty or representation for any particular purposes The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warning...

Page 3: ...EN INCORRECTLY USED E G INDOORS WITHOUT ADEQUATE AIR CIRCULATION OR IF NOT PROPERLY WORKING CO POISONING MAY LEAD TO DEATH GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTION...

Page 4: ...et Weight kg 40 8 Length mm 1215 Width mm 580 Height mm 705 Tank Capacity l 69 Operating range h 7 Standard Accessories Fuel gauge yes Handle 1 Ambient thermostat built in Malfunction detection signal...

Page 5: ...of at least 25 cm kW equally distributed between floor and high level with a minimum of 250 cm BGO 100A 16 F Minimum Opening Size 2500 cm Only install the heater in normal upright position Do not pla...

Page 6: ...FF O position The post ventilation phase will cool down the combustion chamber for 90 seconds Unplug the unit when not used for a long time Never disconnect the heater from mains to stop it while in o...

Page 7: ...er into the heater Never use solvents gasoline toluene and similar aggressive chemicals to clean the heater The following checks BY QUALIFIED PERSONNEL ONLY are recommended before every seasonal use F...

Page 8: ...usted by qualified technicians only Tampering with the unit may be dangerous Remove pressure gauge cap P Connect a pressure gauge on the pressure measuring port on pump Start heater and read fuel pres...

Page 9: ...e setting pressure on fuel pump Fig 6 This setting adjustment can be necessary to prevent excessive smoke emission due to lack of Oxygen Fig 7 Electrical Inspect cables electrical parts and connection...

Page 10: ...ged Clean nozzle blowing compressed air replace if necessary Fuel viscosity increased at low temperature Mix Diesel with 10 20 kerosene Heater starts but combustion is not good Insufficient airflow in...

Reviews: