
+44 (0)23 8052 2345
34
MV Heating UK Ltd
Remote Operation
When the remote signal had been received, the timer will automatically
switch to the thermostatic mode, with a default temperature of 25°C, the
confirmation dot will appear in the meantime.
To return back to the standby mode, press the heating icon. The confirmation
dot will continue to appear until the remote shutdown signal has been
received.
Installation Fuel Priming Feature
ATTENTION
:
•
Not to be used in normal heater operation
•
Disconnect the fuel line from the heater first, to prevent flooding of
the heater and place in a suitable receptacle.
To enter the fuel priming mode, press and hold the ‘P’ icon for more than
three seconds and let go to enter the next step.
Next, press and hold the heating icon for more than three seconds and then
let go. If done correctly the display will read ‘FUEL’ and
the pump will begin to
pump quickly. To stop; press the heating icon again.
Press and hold the ‘P’ icon for more than three seconds to return to the
standby mode.