© MuxLab Inc.
Active VGA Managed Repeater Hub Installation Guide
Page 23
5.
Appendix
ASCII Command Set
Ensure that the terminal emulation program parameters
are set to the following:
BAUD Rate:
9600
Data
bits:
8
Stop
bits:
1
Parity:
None
Flow control:
None
It should be noted that commands are case sensitive and
arguments must be separated by a single space.
Characters that are not supported will be rejected by the
response:
ILLEGAL CHARACTER
. Commands must
be entered in the following way and ended with a
carriage return:
version
Description:
Returns MuxLab product number & firmware version
Example:
version
Arguments:
[none]
Response:
500XXX Version Y.Y.Y
500XXX
MuxLab part number
Y.Y.Y
Firmware
version
Example: