![MUTOH VJ-1638UH Mark II Installation Manual Download Page 5](http://html.mh-extra.com/html/mutoh/vj-1638uh-mark-ii/vj-1638uh-mark-ii_installation-manual_1860224005.webp)
VJ-1638UH Mark
Ⅱ
INSTALLATION MANUAL
5
VJ1638UH2E-I-02
4. Insert the U-shaped part of the media support bar
into the frame.
4 Installation
(2) When not using the media-feed table
Procedures and environment for installing this product
are explained.
On a shaky stand
Slanting location
Places where vibration of other
machines etc. is transmitted.
4.1 Installation environment
4.2 Installation procedure
4.2.1 Installing the printer main unit
1. Carry the printer to the installation place.
2. Turn the following adjusters in the direction as
shown below to prevent the printer from moving.
Stand: adjusters (4)
3. Set the level on the right and left platens and
adjust so that the printer stays flat.
4. Check that the two-way valve of the drain tube is
closed. Hook the two-way valve on the clamp,
then close the clamp cover.
Install this product to the installation place in
accordance with the list shown below.
4.1.1 Installation environmental condition
4.1.2 Installation space
It has enough strength to support the weight of the
printer and the stand.
For the weight of the printer and the stand, refer to
the Operation Manual.
Install on a level floor which meets the following condition.
Select an installation location in accordance with the
table below.
Floor strength of
installation place
More than 2940 Pa (300 kg/m
2
)
AC100-240V
50/60Hz ± 1Hz
100V-240V: 10.0 A - 4.0A
Temperature: 20 °C to 32 °C
Humidity: 40% to 60%, No Condensation
Temperature: within 2 °C per one hour
Humidity: within 5% per one hour
Temperature: 22 °C to 30 °C
Humidity: 40% to 60%, No Condensation
For temperature and humidity, avoid locations
such as the following. There is a possibility that
the print quality will be affected.
Places where temperature or humidity may rapidly
change, even though within the required conditions.
Places that receive direct sunlight, increased
illumination or direct air, for example from an air
conditioner.
To keep the temperature and humidity constant,
install this product in a location where the air
condition is adjustable.
Install this product to the appropriate place with
reference to the following.
Do not install the printer in the following places
where there is a possibility that the printer may
be damaged or might fall or be fallen by chance.
Do not step on the printer or place heavy
things on top of it.
It may cause an injury if the printer falls down.
Do not block the vent by covering the printer
with cloths, such as a blanket or tablecloth. If
the vent is blocked, heat may accumulate
inside the printer and it may cause fire.
Do not install the printer in a location that
has high humidity or is dusty.
It could lead to electric shock and fire.
6. Use the thumb screw to fix Stopper on Frame.
7. Use the screws (2 pieces each) and fix Installation
plates (R and L) on Frame.
Install Installation plates on the opposite side of rail
fixing screw.
8. Assemble the other side of media-feed table in the
same way.
・
Install Stopper on the side of rail retaining screw.
・
Install Stopper so that the curved part matches
Frame.
Insert the screws from below.
5. Insert the screws (one for each hole).
Power
Specifiction
Change rate
Current
consumption
Frequency
range
Rated voltage
Operative
condition
Printing
accuracy
coverage
Environ-
mental
conditions
WARNING
NOTE
NOTE
(1) When using the media-feed table
1,000mm
1,000mm
1,000mm
1,000mm
2,983mm
4,983mm
2,730mm
4,730mm
1
2
3
4
2
3
Close
1
2
1
1,000mm
1,000mm
1,000mm
1,000mm
4,983mm
818mm
2,818mm
2,983mm
1
1
2
1
2
2
1
1
1
2
1
3
3
3
1
2
Installation plates (R)
Name
Installation plates (L)
No.
Name
No.
1
2
Frame
Screw
3
4
Frame
Name
Stopper
No.
Name
No.
1
2
Thumb screw
Rail retaining screw
3
Media support bar
Name
No.
Name
No.
1
Screws
2
Media support bar
Name
No.
Name
No.
1
Frame
2
4
Adjusters
Name
No.
Name
No.
1
Stand
2
Level
Name
No.
Name
No.
1
Adjusters
2
Two-way valve
Name
No.
Name
No.
1
Two-way valve clamp
2