OPERATION

Selecting the basic Clock Frequency

Operating the SMART CLOCK and SMART CLOCK av is very simple. 
Select the required basic clock frequency for your studio set-up with the 
frequency selector switches depicted in the following figure.
 
First use the WC SELECT switch to choose 32.0kHz, 44.1kHz or 48.0kHz 
for the basic clock rate. The appropriate LED will be illuminated. By using 
the switch next to the LED, the previously selected clock rate can be 
multiplied by the factors of x1, x2 and x4. For the x2 and x4 settings, the 
appropriate LEDs, WCx2 and WC4, will light up. In this manner, all Word 
Clock frequencies ranging from 32.0kHz to 192.0kHz can be set. The clock 
rate selected here serves as the basic setting for all Word Clock and audio 
signals.
The factory default is set at 44.1kHz, setting the WC SELECT switch 
at its center position (44.100Hz LED is illuminated) and the clock rate 
multiplication switch to its lowest setting (x1).

Selecting the Front-Panel Output Signal

Two additional clock outlets are located on the front panel of the SMART 
CLOCK and SMART CLOCK av. With the help of the two switches shown in 
the illustration, these can be set individually, independent of the outlets on 
the rear panel of the device.

Select the desired output signal type with the right-hand switch:

VIDEO,
The video clock signals set for the video generator are sent out through 
the front-panel outlets (only active for SMART CLOCK with built-in P/NVSG 
option)

x256,
This setting multiplies basic clock rates from 32.0kHz to 96.0kHz by a factor 
of 256. ProTools™ systems manufactured by Digidesign generally require 
such high-output frequencies for synchronization.

WC,
Standard Word Clock signals are output here. The function of this switch 
depends on the setting of the left-hand switch.

Select the Word Clock multiplication factor for both front-panel outlets 
with the left-hand switch: 

x1, x2, x4,
These factors refer to the previously set Word Clock basic signal. i.e. Using 
the factory setting of 44.1kHz as a reference, this clock rate can also be 
output as 88.2kHz (x2) or 176.4kHz (x4).

The output clock signal is always present at both front-panel clock outlets.

For information concerning the SMART CLOCK and SMART CLOCK av 
compatible output clock rates, please consult the »Frequency Tables« in the 
appendix.

Selecting the Rear-Panel Output Signals

As previously described, different output clock signals can be applied to the 
rear-panel clock outlets on the SMART CLOCK and SMART CLOCK av. Please 
also note that signal switching always refers to each set of vertically-aligned 
clock outputs. Thus, the following output groups are formed:

Group 1: OUT 1
Group 2: OUT 2
Group 3: OUT 3

As rear-panel connections are generally used for permanent cable 
connections, these signal selector switches are located inside the device.

13  

Rear-Panel Output Signal select

Front-Panel Output Signal select

Basic clock frequency select

Summary of Contents for SMART DIGITAL SMART CLOCK

Page 1: ......

Page 2: ......

Page 3: ...y subsequently purchase this product No other person retail dealer distributor etc shall be entitled to give any warranty promise on behalf of MUTEC GmbH 3 Waranty regulations The return of the comple...

Page 4: ......

Page 5: ...RATION Selecting the Basic Clock Frequency 13 Selecting the Front Panel Output Signal 13 Selecting the Rear Panel Output Signal 13 Output of PAL NTCS Video Signals 14 Selecting Pull Up Pull Down Facto...

Page 6: ......

Page 7: ...he individual clock signals generated are synchronized to each other in phase and hence feature the same frequency accuracy and time base The frequency generation is accurate to 1ppm and thus complies...

Page 8: ...Applications A V synchronization Low jitter clock signal distribution Multiple clock rate synchronization Film video and audio transfers 8...

Page 9: ...N INSTALLED 6 SMART CLOCKav only This enables you to change the sign of the pull up and pull down frequencies with reference to the percentage of deviation from the basic clock rate described in 7 7 4...

Page 10: ...t impedance is 110 XLR connector male 5 230V 115V This compartment houses the mains fuses which must be inserted in accordance with the local voltage used for operating the unit See also the safety in...

Page 11: ...terminating resistor Most Word Clock or video inputs allow for enabling disabling the termination with a so called termination switch which may be located on the outside or inside of the device For de...

Page 12: ...value when purchasing the cables Connect the optical S PDIF interface with the help of Toshiba TOSLINK compliant optical fiber cables Here you can use both plastic and glass fiber based cables When us...

Page 13: ...r are sent out through the front panel outlets only active for SMART CLOCK with built in P NVSG option x256 This setting multiplies basic clock rates from 32 0kHz to 96 0kHz by a factor of 256 ProTool...

Page 14: ...rmats PAL B G 25fps 625 lines NTSC 29 97fps 525 lines The factory setting is PAL B G The video signal type can also be selected PAL NTSC black burst PAL NTSC composite sync The factory setting is PAL...

Page 15: ...k outputs of the signal distributor s see illustration below To disable the delay units please following the instructions given in the appendix section Switching over of the Rear Panel Output Signals...

Page 16: ...16...

Page 17: ...nnect the power cord from both the wall outlet and the unit before you attempt to replace the mains fuse Make sure that the fuse holder is inserted completely down to the bottom of its socket and that...

Page 18: ...ignals by default the black sliders of these switches are set to the left position 2 Use these three switches to set the various clock rates for the output pair located before them According to the nu...

Page 19: ...Sync The factory default is black burst 2 Use this slide switch to select the basic video signal PAL oder NTSC The factory default is PAL NTSC PAL Please note that video signal selection always refers...

Page 20: ...scillator burned in and pre aged Clock accuracy shipped 1 0ppm aligned to AES11 grade1 Operating temperature 10 C to 60 C FREQUENCY SYNTHESIS PROCESSING Frequency synthesis Digital synthesized phase l...

Page 21: ...z 44 1kHz 44 1kHz 88 2kHz 176 4kHz 11 2896MHz 48 0kHz 48 0kHz 96 0kHz 192 0kHz 12 2880MHz 64 0kHz 64 0kHz 128 0kHz 256 0kHz 16 3840MHz 88 2kHz 88 2kHz 176 4kHz 352 8kHz 22 5792MHz 96 0kHz 96 0kHz 192...

Page 22: ......