Unplug the UPS prior to cleaning and do not use liquid or spray 
detergent. 

 

Do  not  dispose  of  battery  or  batteries  in  a  fire.    The  battery  may 
explode. 

 

Do  not  open  or  mutilate  the  battery  or  batteries.    Released 
electrolyte is harmful to the skin and eyes.    It may be toxic. 

 

A battery can present a risk of electrical shock and high short circuit 
current. The following precautions should be observed when working 
on batteries : 

1)

 

Remove watches, rings, or other metal objects from the hand. 

2)

 

Use tools with insulated handles. 

3)

 

Wear rubber gloves and boots. 

4)

 

Do not lay tools or metal parts on the top of batteries. 

5)

 

Disconnect charging source prior to connecting or disconnecting 
batteries terminal. 

 

Servicing of batteries should be performed or supervised by personnel 
knowledgeable  of  batteries  and  the  required  precautions.    Keep 
unauthorized personnel away from batteries. 

 

When  replacing  batteries,  replace  with  the  same  number  of  the 
sealed lead-acid batteries. 

 

This pluggable type A equipment with battery already installed by the 
supplier is operator installable and may be operated by laymen. 

 

During the installation of this equipment it should be assured that the 
sum of the leakage currents of the UPS and the connected loads does 
not exceed 3.5mA. 

 

The mains socket outlet that supplies the UPS shall be installed near 
the UPS and shall be easily accessible. 

 

WARNING: This is a UPS Class C2. In residential subdivision the product may 
cause harmful interference, then the users have to take additional measures.” 

 

Summary of Contents for Power Must 400

Page 1: ...USER MANUAL Power Must 400 600 800 LCD Uninterruptible Power System...

Page 2: ...osition and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid co...

Page 3: ...g or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away fro...

Page 4: ...System Description Front Panel 1 LCD Back Light 2 Power ON OFF Switch Back Panel 1 Communication Port optional 2 Modem Phone Line Surge Protection 3 AC Output 4 AC Input...

Page 5: ...the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an envir...

Page 6: ...internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the...

Page 7: ...h ON The LED lighting 8 LCD Display Specification The LED will always turns on when UPS works including in off charging mode and fault mode When LCD start to work it will display all information for 3...

Page 8: ...40V input voltage will display 000 4 When in off charging mode it will display as below Note the output voltage always is displayed as 000 in off charging mode 5 When in fault mode it will display as...

Page 9: ...100 7 Battery capacity definition Battery LEVEL Battery bar Indication Battery voltage 11V 11V Battery voltage 11 5V 11 5V Battery voltage 12 5V Battery voltage 12 5V 8 When over load the mark will fl...

Page 10: ...that the load matches the UPS capability specified in the specs 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 8 hours or more When power failure b...

Page 11: ...CD Display Models Including in off charging mode and fault mode Backup Mode Sounding every 10 seconds Battery Low Sounding every 1 second Overload Sounding every 0 5 seconds Battery replace Sounding e...

Reviews: