Installation and Operation 

 

Installing  the  UPS  is  as  easy  as  following  the  steps  shown.    Be 
aware  of  the  Power  Switch  must  be  kept  in  the  “ON”  position, 
otherwise, the UPS will be disabled and your equipment will not be 
protected during a power failure. 

 

1.

 

Inspection 

Remove  the  UPS  from  its  packaging  and  inspect  it  for  damage  that 
may  have  occurred  during  shipping.  If  any  damage  is  discovered, 
repack the unit and return it to the place of purchase. 

 

2. 

Placement 

Install  the  UPS  unit  in  any  protected  environment  that  provides 
adequate  airflow  around  the  unit,  and  is  free  from  excessive  dust, 
corrosive  fumes  and  conductive  contaminants.  Do  not  operate  your 
UPS in an environment where the ambient temperature or humidity is 
high. On the other hand, place the UPS unit away from monitor at least 
20cm to avoid interference. 
 

3. 

Charging 

 

This  unit  is  shipped  from  the  factory  with  its  internal  battery  fully 
charged.  however,  some  energy  may  be  lost  during  shipping  so  the 
battery  should  be  recharged  before  using  it.  Plug  the  unit  into  an 
appropriate power supply and allow the UPS to charge fully by leaving 
it plugged in for 8 hours.

 

 

8 hours

 

 
 
 
 
 
 

Summary of Contents for Power Must 400

Page 1: ...USER MANUAL Power Must 400 600 800 LCD Uninterruptible Power System...

Page 2: ...osition and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid co...

Page 3: ...g or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away fro...

Page 4: ...System Description Front Panel 1 LCD Back Light 2 Power ON OFF Switch Back Panel 1 Communication Port optional 2 Modem Phone Line Surge Protection 3 AC Output 4 AC Input...

Page 5: ...the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an envir...

Page 6: ...internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the...

Page 7: ...h ON The LED lighting 8 LCD Display Specification The LED will always turns on when UPS works including in off charging mode and fault mode When LCD start to work it will display all information for 3...

Page 8: ...40V input voltage will display 000 4 When in off charging mode it will display as below Note the output voltage always is displayed as 000 in off charging mode 5 When in fault mode it will display as...

Page 9: ...100 7 Battery capacity definition Battery LEVEL Battery bar Indication Battery voltage 11V 11V Battery voltage 11 5V 11 5V Battery voltage 12 5V Battery voltage 12 5V 8 When over load the mark will fl...

Page 10: ...that the load matches the UPS capability specified in the specs 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 8 hours or more When power failure b...

Page 11: ...CD Display Models Including in off charging mode and fault mode Backup Mode Sounding every 10 seconds Battery Low Sounding every 1 second Overload Sounding every 0 5 seconds Battery replace Sounding e...

Reviews: