11
7)
IMPORTANT!
Bobbin (yellow) must be installed into the
HOUSING (***Fig. 9), white side up, aligning the slots on the
bobbin with the ridges inside the threaded housing. The bobbin
will slide in.
8) Install cap by screwing clockwise until it meets the housing
shoulder.
9) Check the new cylinder/bayonet assembly to ensure the o-ring is
in place and the sensor ring is attached (Fig. 9). Ensure that the
CO
2
cylinder has not been pierced (Fig. 10).
IMPORTANT: You will damage the sensor ring if bobbin
and cap are not installed first.
Service
Indicator
Groove
Pull-cord
Tab
Piercing
Pin
Cylinder
MD2017 Automatic Inflator
1/8 Turn
Figure 11
10) Push, and hold, the lever into the inflator housing. The pull-cord
should be situated in the groove (Fig. 11). Install a new cylinder/
bayonet assembly by engaging bayonet tabs in housing, pushing
in then turning clockwise 1/8 turn to a full stop (Fig. 11).
WARNING: PFD WILL ONLY INFLATE IF CYLINDER IS
TURNED TO A FULL STOP.
11) Examine the service indicator (Fig. 9) and ensure it is GREEN. If
the service indicator is red, the mechanism has been fired or is
incorrectly fitted and the inflator requires service.
NOTE: The service indicator must be green before
proceeding.
HT3160_MD2015_MD2017_28AUG2015.indd 11
28/08/2015 10:39:34 AM