ABOUT THIS MANUAL
Purpose

This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read this manual 
carefully before installations and operations. Keep this manual for future reference.

Scope

This manual provides safety and installation guidelines as well as information on tools and wiring.

The following cases are not within the scope of warranty

1. Out of warranty.
2. Series number was changed or lost.
3. Battery capacity was declined or external damaged.
4. Inverter was damaged caused of transport shift, remissness, ect external factor
5. Inverter was damaged caused of irresistible natural disasters.
6. Not in accordance with the electrical power supply conditions or operate environment caused damage.

SAFETY INSTRUCTIONS

             WARNING: This chapter contains important safety and operating instructions. Read and keep 
             this manual for future reference.

1.   Before using the unit, read all instructions and cautionary markings on the unit the batteries and all appropriate 
      sections of this manual.
2. 

  CAUTION 

--To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types 

      of batteries may burst, causing personal injury and damage.
3.   Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect 
      re-assembly may result in a risk of electric shock or fire.
4.   To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning 
      off the unit will not reduce this risk.
5. 

  CAUTION

 --Only qualified personnel can install this device with battery.

6. 

  NEVER

 charge a frozen battery.

7.   For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It' s 
      very important to correctly operate this inverter/charger.
8.   Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to 
      spark or short circuit batteries or other electrical parts and could cause an explosion.
9.   Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to 
      INSTALLATION section of this manual for the details.
10. Fuses (1 piece of 200A, 58VDC for 3KW,4KW and 5KW) are provided as over-current protection for the battery 
      supply.    
11. GROUNDING INSTRUCTIONS- This inverter/charger should be connected to a permanent grounded wiring 
      system. Be sure to comply with local requirements and regulation to install this inverter.
12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
13. 

Warning!!

 Only qualified service persons are able to service this device. If errors still persist after following 

      troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

1

28

TROUBLE SHOOTING

Problem

LCD/LED/Buzzer

Explanation / Possible cause

What to do

The battery voltage is too low
( < 1.91V/Cell)

1. Re-charge battery.
2. Replace battery.

No response after 
power on.

No indication.

1. The battery voltage is far too low. 
(<1.4V/Cell)
2. Battery polarity is connected 
reversed. Input protector is tripped

1. Check if batteries the wiring 
are connected and well.
2. Re-charge battery.
3. Replace battery.

Mains exist but the 
unit works in battery 
mode.

Input voltage is 
displayed as 0 on the 
LCD and green LED 
is flashing.

Insufficient quality of AC power
(Shore or Generator)

Check if AC breaker is tripped 
and AC wiring is connected 
well.

1. Check if AC wires are too 
thin and/or too long.
2. Check if generator (if 
applied) is working well or if 
input voltage range setting is 
correct.(Appliance=>wide)

Input protector is tripped

When the unit is 
turned on, internal 
relay is switched on 
and off repeatedly.

LCD display and LEDs 
are flashing

Battery is disconnected.

Check if battery wires are 
connected well.

Buzzer beeps 
continuously and 
red LED is on.

Fault code 07

Overload error. The inverter is 
overload 110% and time is up.

Reduce the connected load by 
switching off some equipment.

Fault code 05

Output short circuited.

Fault code 02

Internal temperature of inverter 

o

component is over 90 C.

Check whether the air flow of 
the unit is blocked or whether 
the ambient temperature is too 
high.

Check if wiring is connected 
well and remove abnormal 
load.

Fault code 03

Battery is over-charged.

Return to repair center.

The battery voltage is too high.

Check if spec and quantity of 
batteries are meet 
requirements.

Fault code 01

Fan fault

Fan fault

Fault code 06/58

1. Reduce the connected load.
2. Return to repair center

Output abnormal (Inverter voltage 
below than 202Vac or is higher than 
253Vac)

Fault code 
08/09/53/57

Internal components filed.

Return to repair cente

Fault code 51
Fault code 52

Fault code 55

Fault code 56

Over current or surge

Bus voltage is too low

Output voltage is unbalanced

Battery is not connected well or 
fuse is burnt.

If the battery is connected well, 
please return to repair center.

Restart the unit, if the error 
happens again, please return
 to repair center.

Unit shuts down 
automatically during 
startup process.

LCD/LEDs and buzzer 
will be active for 3 
seconds and then 
complete off.

Green LED is flashing.

Summary of Contents for PV18 MPPT 3 KW

Page 1: ...420 00314 A1 3KW 5KW ...

Page 2: ...pecifications 24 Table 3 Charge Mode Specifications 26 Table 4 General Specifications 27 TROUBLE SHOOTING 28 Appendix Approximate Back up Time Table 29 29 Appendix Approximate Back up Time Table Model Load W Backup Time 48Vdc 100Ah min Backup Time 48Vdc 200Ah min 4KW 400 5KW 800 1200 1600 2000 2400 2800 3200 3600 4000 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 766 335 198 139 112 95 81 62 55...

Page 3: ...r 12 NEVER cause AC output and DC input short circuited Do NOT connect to the mains when DC input short circuits 13 Warning Only qualified service persons are able to service this device If errors still persist after following troubleshooting table please send this inverter charger back to local dealer or service center for maintenance 1 28 TROUBLE SHOOTING Problem LCD LED Buzzer Explanation Possi...

Page 4: ... for optimized battery performance Cold start function Basic System Architecture The following illustration shows basic application for this inverter charger It also includes following devices to have a complete running system Generator or Utility PV modules option Consult with your system integrator for other possible system architectures depending on your requirements This inverter can power all...

Page 5: ... cations Utility Charging Mode Charging Current Nominal Input Voltage Absorption Voltage AGM Gel LEAD Battery Flooded battery AGM Gel LEAD Battery Flooded battery AGM Gel LEAD Battery Flooded battery Re oat Voltage Float Voltage Charging Algorithm 33 Step Flooded Battery AGM Gel LEAD Battery 4 Step LI Solar Charging Mode INVERTER MODEL Rated Power MPPT charger solar charging current Max PV Array O...

Page 6: ...on is to be adhered to the wall vertically Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires SUITABLE FOR MOUNTING ON CONCRETE OROTHER NON COMBUSTIBLE SURFACE ONLY 25 Output power derating When AC input voltage drops to 95V or 170V depending on models the output power will be derated Transfer Time...

Page 7: ...d cable and terminal size as below Recommended battery cable and terminal size 24 Display Setting The LCD display information will be switched in turns by pressing UP or DOWN key The selectable information is switched as below order battery voltage battery current inverter voltage inverter current grid voltage grid current load in Watt load in VA grid frequency inverter frequency PV voltage PV cha...

Page 8: ...Grid state The inverter will provide output power from battery and PV power Inverter power loads from PV energy Inverter power loads from battery and PV energy Inverter power loads from battery only Stop mode The inverter stop working if you turn off the inverter by the soft key or error has occurred in the condition of no arid Operating State Description Operating State Description LCD display Ma...

Page 9: ...nection 1 Before making AC input output connection be sure to open DC protector or disconnector first 2 Remove insulation sleeve 10mm for six conductors And shorten phase L and neutral conductor N 3mm 3 Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws Be sure to connect PE protective conductor first Ground yellow green L LINE brown or black ...

Page 10: ... inverters are worked in parallel operation CAUTION Appliances such as air conditioner are required at least 2 3 minutes to restart because it s required to have enough time to balance refrigerant gas inside of circuits If a power shortage occurs and recovers in a short time it will cause damage to your connected appliances To prevent this kind of damage please check manufacturer of air conditione...

Page 11: ...lect programs And then press ENTER button to exit Reset setting disable 23 Backlight control 24 Alarm control Alarm on default Backlight on Backlight off default Alarm off 25 Beeps while primary source is interrupted Alarm on Alarm off default 27 Record Fault code Record enable default Record disable Reset setting enable 20 Fault Reference Code Fault Code Fault Cause LCD Indication 01 02 03 04 Fan...

Page 12: ...c model Increment of each click is 0 1V Low DC cut off battery voltage setting 19 48V model default setting 40 8V If self defined is selected in program 14 this program can be set up Setting range is from 40 0V to 48 0V for 48Vdc model Increment of each click is 0 1V Low DC cut off voltage will be fixed to setting value no matter what percentage of load is connected 19 If selected the display scre...

Page 13: ...rce no matter utility is available or not If this inverter charger is working in Battery mode only solar energy can charge battery Solar energy will charge battery if it s available and sufficient 08 If this inverter charger is working in Line Standby or Fault mode charger source can be programmed as below 60A default Setting range is from 1 A to 120A Increment of each click is 1A 11 18 80A defaul...

Page 14: ...int in program 21 for 5 minutes and the solar energy has been available for 5 minutes too the inverter will turn to battery mode solar and battery will provide power to the loads at the same time When the battery voltage drops to the setting point in program 20 the inverter will turn to bypass mode utility provides power to the load only and the solar will charge the battery at the same time Utili...

Page 15: ...ng mode Escape default Output source priority selection 01 16 Solar energy provides power to the loads as first priority If solar energy is not sufficient to power all connected loads Utility energy will supply power to the loads at the same time The battery energy will supply power to the load only in the condition of the utility is unavailable If the solar is unavailable the utility will charge ...

Page 16: ...indicates the AC information Indicates the DC information Indicate input voltage input frequency PV voltage battery voltage and charger current Indicate output voltage output frequency load in VA load in Watt and discharging current Configuration Program and Fault Information Indicates the setting programs Iindicates the warning and fault codes Warning flashing with warning code Fault lighting wit...

Reviews: