13
Maximum utility charging current
30A (default)
Setting range is from 1A to 60A.
Increment of each click is 1A.
AGM (default)
Battery type
14
Flooded
GEL
LEAD
Lithium Ion
User-Defined
If "User-Defined" LI is selected, battery charge voltage and low
DC cut-off voltage can be set up in program 17, 18 and 19.
Bulk charging voltage
(C.V voltage)
17
If self-defined is selected in program 14, this program can be set
up. Setting range is from 48.0V to 58.4V for 48Vdc model.
Increment of each click is 0.1V.
48V model default setting: 56.4V
48V model default setting: 54.0V
Floating charging voltage
18
If self-defined is selected in program 14, this program can be set
up, Setting range is from 48.0V to 58.4V for 48Vdc model.
Increment of each click is 0.1V.
Low DC cut off battery voltage
setting
19
48V model default setting: 40.8V
If self-defined is selected in program 14, this program can be set
up. Setting range is from 40.0V to 48.0V for 48Vdc model.
Increment of each click is 0.1V. Low DC cut-off voltage will be
fixed to setting value no matter what percentage of load is
connected.
19
If selected, the display screen will stay
at latest screen user finally switches.
20
Battery stop discharging voltage
when grid is available
Available options for 48V models:
46.0V (default)
Setting range is from 44.0V to 58.0V.
Increment of each click is 0.1V.
Battery stop charging voltage
when grid is available
21
Available options for 48V models:
Setting range is from 44.0V to 58.0V.
Increment of each click is 0. 1V.
54.0V (default)
Auto turn page
(default)
If selected, the display screen will auto
turn the display page.
22
10
MPPT-80A
Summary of Contents for PV18 MPPT 3 KW
Page 1: ...420 00314 A1 3KW 5KW ...