Muskoka MFBC42WS Use And Care Manual Download Page 3

USER INSTRUCTIONS

 

1.

   Any repairs to this appliance should be carried out by qualified/authorized service personnel only.

 2. 

 Under no circumstances should this appliance be modified Parts having to be removed for servicing  

    must be replaced with original “OEM” (original equipment manufacturers) parts only.

 3.

  This firebox is to be cleaned with a damp cloth (water) only. 

IMPORTANT:

 Always unplug the power cord before cleaning the unit. Do not use any abrasive cleaners 

on the unit.

 

4.

  Please unplug this firebox when not in use.

Grounding Instructions

This heater is for use on 120 volts. The cord has a plug as shown 

in figure 1A in the diagram. An adapter as shown in figure 1C is 

available for connecting three-blade grounding-type plugs to two-slot 

receptacles. The green grounding lug extending from the adapter must 

be connected to a permanent ground such as a properly grounded 

outlet box. The adapter should not be used if a three-slot grounded 

receptacle is available.

Locating Your Fireplace

When choosing a location for your new fireplace, ensure the general 

instructions are followed. Also, for best effect install the fireplace out 

of direct sunlight.

It is safe to set the fireplace insert close to non-combustibles. 

DO NOT STORE OR USE GASOLINE OR 

OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

Mantel Installation

Please refer to the detailed instructions that come with the mantel that you purchased.

Specifications

MFBC42WS
Fireplace Insert dimensions 

(w x d x h)

43” x 5.1”x 18.1”

109,1cm x 12,9cm x 45,9cm

Gross Weight

37.9 lbs / 17,2 kg

Voltage

120 V

Frequency

60 Hz

Watts / Amps.

1400 W / 11.6 A

Heater Rating

1400W / 4777 BTU's

Electrical Connection

A 15 Amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required to operate this appliance. 

Preferably, the fireplace insert will be on a dedicated circuit as other appliances on the same circuit 

may cause the circuit breaker to trip or the fuse to blow when the heater is in operation. The unit comes 

2

Fig. 1

Grounding Pin 
Cover of Grounded Outlet Box

Adapter
Grounding Lug
Metal Screw 
Cover of Grounded Outlet Box

A

B

C

Summary of Contents for MFBC42WS

Page 1: ...ire may result causing property damage personal injury or loss of life Veuillez lire ce manuel avant l installation et l utilisation de votre foyer Si les renseignements de ce manuel ne sont pas exact...

Page 2: ...ctrical or mechanical adjustment or repair 6 Do not use outdoors 7 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall int...

Page 3: ...vailable Locating Your Fireplace When choosing a location for your new fireplace ensure the general instructions are followed Also for best effect install the fireplace out of direct sunlight It is sa...

Page 4: ...e performed by qualified authorized service personnel only Glass Information 1 Under no circumstances should this product be operated with a broken or chipped glass panel 2 Do not strike or slam the g...

Page 5: ...he power button 1 again will turn the power off Using the flame button Pressing the flame control button 2 once turns flames on and lights the ember bed Continue to press the flame control button 2 to...

Page 6: ...3 C 27 C ON 17 C 18 21 C Once you ve selected your desired temperature the display will flash 5 times and exit the adjustment mode Once the desired room temperature is reached the heater will deactiva...

Page 7: ...ns of this limited warranty shall not apply to the following 1 Accidents 2 Unauthorized repairs or alterations 3 Normal maintenance 4 Changes made to other units manufactured after this mantel was man...

Page 8: ...iliser l ext rieur 7 Cet appareil de chauffage n a pas t con u pour tre utilis dans une salle de bain une salle de lavage ni pour tout autre endroit similaire l int rieur Ne jamais placer cet appareil...

Page 9: ...it tre raccord e une mise la terre permanente prise de courant mise la terre L adaptateur ne doit pas tre utilis si une prise trois fentes mise la terre est disponible Positionnement de votre manteau...

Page 10: ...rifier le manteau de foyer et pour faire remplacer les pi ces du syst me lectrique qui ont t immerg es Instructions d entretien Pour votre s curit L entretien de l appareil doit tre assur par un perso...

Page 11: ...n de flammes ou de chauffage et elle ne peut tre utilis e pour convertir l affichage de la temp rature en Fahrenheit ou en Celsius 1 Bouton d alimentation 2 Bouton de commande des flammes 3 Bouton de...

Page 12: ...d sir e l affichage clignotera 5 fois et quittera le mode d ajustement Quand la pi ce atteint la temp rature d sir e l appareil de chauffage se d sactivera Pour afficher le param tre de temp rature e...

Page 13: ...e ce remplacement ou ces r parations Les dispositions de cette garantie limit e ne s appliquent pas aux dispositions suivantes 1 Accidents 2 R parations ou modifications non autoris es 3 Entretien nor...

Page 14: ...alentador no est destinado a ser usado en ba os zonas destinadas a la lavander a y ubicaciones interiores similares Jam s debe ubicar el calentador en una posici n en la que se pueda caer en una ba er...

Page 15: ...prende del adaptador debe estar conectada a una conexi n a tierra permanente como por ejemplo una caja de toma de corriente que tenga una conexi n a tierra adecuada No deber usar este adaptador cuando...

Page 16: ...mediato al servicio t cnico calificado para que revise la caja de fuego y que reemplace cualquier parte del sistema el ctrico que estuvo sumergida Instrucciones para su mantenimiento Para su seguridad...

Page 17: ...dad Uso del bot n de llama Pulsando el bot n de control de llama 2 una vez se enciende la llama y se alumbra el lecho de brasas Contin e pulsando el bot n de control de llama 2 para ver los diferentes...

Page 18: ...z que la habitaci n haya alcanzado la temperatura deseada la calefacci n se desactivar Para mostrar las configuraciones de temperatura en Fahrenheit o Celsius pulse el bot n de calor en el control de...

Page 19: ...siguientes 1 Accidentes 2 Reparaciones o modificaciones no autorizadas 3 Mantenimiento normal 4 Modificaciones que se ejecutaron en otras unidades fabricadas despu s de fabricar este Repisa de chimen...