The trigger detection parameters, reverb effect, EQ, MIDI set up,
reset to factory default can be set in UTILITY menu. Press
[UTILITY] button to enter the utility menu:
Explain Details:
Sensitive
Adjust the sensitivity of the pad to regulate the pad response.
Higher settings result in higher sensitivity, so that the pad will
produce a loud volume even when struck softly. Lower sensitivity
will keep the pad to producing a low volume even when played
forcefully. You can also adjust the sensitivity of the splash in
Splash Sensitivity.
Threshold
This setting allows a trigger signal to be received only when the
pad is struck harder than a specified force. This can be used to
prevent a pad from sounding in response to extraneous vibrations
from another pad.
Curve (Trigger curve)
Curve 1:
The most natural setting. There is a linear change
between playing dynamics and volume response.
Curve 2, 3:
Compared to Curve 1, heavily strikings make greater
change.
Curve 4, 5:
Compared to Curve 1, gentle strikings make greater
change
Curve 6:
Even a soft strike can make strong volume, and the
range of dynamic response is small. Especially when a drum
trigger is used as an external pad, reliable triggering can be made.
Trigger
You can set the parameters of each drum pad and cymbals in the
Trigger menu. During the setting, you can select each trigger by
hitting the corresponding trigger or use the Pad select buttons on
the panel. The corresponding panel button of selected pad will light
up. Press the [UITILITY] button, select “TRIGGER” page, and then
press the [SAVE/ ENTER] button to enter parameter page of
currently pad.
Here are the parameters for triggers:
Uitility
31
Operating Guide
[UTILITY]
[SAVE/ ENTER]
[+]
[PAGE +]
[PAGE +]
[PAGE +]
[PAGE +]
[PAGE +]
LCD Display
TRIGGER
Sensitive:1
Sensitive:2
EFFECT
MIDI SET
SAVEGLOBAL
RESET
AUTOPOWER
Description
Trigger detection parameters.
Trigger sensitivity.
Change value.
Reverb and EQ.
MIDI set up.
Save global settings to SD card.
Set global settings to factory
default.
Auto power off.
Parameter
Sensitive*
Thresh*
Curve*
Retrig-C*
X-Talk*
Rim-Adj*
Splash-S
Description
Sensitivity.
Threshold.
Trigger curve.
Retrigger cancel.
Cross talk.
Rim sensitivity.
Splash sensitivity.
Range
1-32
0-31
Normal/Exp1/Exp2/
Logl/Log2/Loud
1-16
0-16
0-16
1-8
Default
-
-
Normal
-
-
-
5
VOL
Striking
Curve1
VOL
Striking
Curve2
VOL
Striking
Curve3
VOL
Striking
Curve4
VOL
Striking
Curve5
VOL
Striking
Curve6
C
M
Y
CM
MY
CY
CMY
K