1. Remove clamps (4/3) and gaskets
(4/4) that connect the suction manifold
to the suction check valves.
2. Remove suction manifold. Repeat
for discharge manifold.
3. Remove all four ball housings (3/2)
by removing clamps (3/4) and gaskets
(3/5). Then remove balls (3/1) and ball
stoppers (3/3) from all check valves.
4. Loosen left product chamber clamp
(2/8) by turning clamp handle (2/9).
5. Remove left product chamber clamp
and left product chamber (2/2). Repeat
for right product chamber. Both pump
diaphragms (2/1) are now exposed.
All wet parts of your Murzan pump
are now exposed for inspection and
cleaning. Continue reading only for
inspection and service of dry parts. To
reassemble wet parts, skip to step 6 of
section 6.0 on Pump Reassembly.
17