![Murzan PI-50 Operation & Service Manual Download Page 30](http://html1.mh-extra.com/html/murzan/pi-50/pi-50_operation-and-service-manual_1858500030.webp)
7. Pull the opposite piston assembly through to the exposed air chamber. Again, fold the diaphragm
inwards until it is flush with the air chamber. Place the product chamber over the diaphragm, install the
product chamber clamp and tighten the clamp handle just enough to hold the product chamber in place.
Again, check the level of the product chamber. Fully tighten the product chamber clamp.
27