Input
13.8
Voltage
27.6
Input
13.8
Voltage
27.6
Input
13.8
Voltage
27.6
Input
13.8
Voltage
27.6
10
1
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
4
0
0
0
0
0
0
0
0
5
13.8
27.6
0
0
0
0
13.8
27.6
6
0
0
13.8
27.6
13.8
27.6
0
0
7
0
0
0
0
0
0
0
0
8
0
0
0
0
0
0
0
0
9
0
0
0
0
0
0
0
0
10
0
0
0
0
0
0
13.8
27.6
11
0
0
0
0
0
0
0
0
12
0
0
0
0
0
0
0
0
13
0
0
0
0
0
0
0
0
14
0
0
0
0
0
0
0
0
15
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
16
0
0
13.8
27.6
0
0
0
0
17
0
0
0
0
0
0
0
0
18
0
0
0
0
0
0
0
0
19
0
0
0
0
0
0
0
0
20
0
0
0
0
0
0
0
0
21
0
0
0
0
0
0
0
0
22
0
0
0
0
0
0
0
0
23
0
0
0
0
0
0
0
0
24
0
0
0
0
0
0
0
0
25
0
0
0
0
0
0
0
0
26
13.8
27.6
0
0
0
0
13.8
27.6
27 (1)
0
0
4
4
4
4
0
0
28 (2)
0
0
0
0
7.5
7.5
0
0
29
0
0
7.5
7.5
7.5
7.5
7.5
7.5
30
0
0
7.5
7.5
7.5
7.5
7.5
7.5
31
0
0
7.5
7.5
7.5
7.5
7.5
7.5
32
0
0
7.5
7.5
7.5
7.5
7.5
7.5
33
0
0
7.5
7.5
7.5
7.5
7.5
7.5
34
0
0
0
0
0
0
0
0
35
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
36
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
37 (2)
13.8
27.6
13.8
27.6
13.8
27.6
0
0
38
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
39
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
40
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
41
0
0
0
0
0
0
0
0
42
0
0
0
0
0
0
0
0
43
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
44
13.8
27.6
13.8
27.6
13.8
27.6
13.8
27.6
45
0
0
0
0
0
0
0
0
46
0
0
0
0
0
0
0
0
N
OTES
Note 1: AC voltage measured on AC scale of volt-ohmmeter.
Note 2: Low Oil Pressure shutdown circuit.
Oil pressure was the cause of shutdown on column 4.
Table 7-2.1
Mode
Selector
OFF
Mode Selector
START
Cranking
Mode Selector
RUN
Running
Mode Selector
RUN
Shutdown
Terminal
Number