Description

1. AS3000

Automatic Controller

2. AC Ampmeter

AC Amps 

3. AC Voltmeter

AC Volts 

4. Phase Switch

1-3 Phase Selector Switch 

5. Frequency Meter

45-65 Hertz 

6. Pressure Gage

0-100 psi 

7. Temperature Gage

0-250 °F 

8. DC Hourmeter

DC hourmeter 

9. DC Voltmeter

DC Volts 

10. Enclosure

Fixed or Hinged door. 

11. Vibration Shocks

Help excesive vibration.   

13-31/32 in.

(355 mm)

5/16 x 1/2 in. (8 x 13 mm)

Mounting Holes, 4-Places

15 in.  

(xxx mm)

10-5/8 in.

(270 mm)

18-63/64 in.

(480 mm)

18-1/2 in.

(470 mm)

kPa

PSI

50

75

100

0

0

25

350

700

kPa

PSI

50

75

100

0

0

25

350

700

QUARTZ

HOURS

kPa

PSI

50

75

100

0

0

25

350

700

OFF/

STOP

REMOTE START
DEMAND

OVERCRANK

ENGINE RUNNING

LOW OIL  
PRESSURE

BATTERY  
CHARGER FAIL

A-C

VOLTS

A-C

AMPERES

HERTZ

HIGH ENGINE  
TEMPERATURE

PLANT FAIL/ 
AUXILIARY INPUT

OVERSPEED

MANUAL

START

AUTO

START

OFF

1

kPa

PSI

50

75

100

0

0

25

350

700

kPa

PSI

50

75

100

0

0

25

350

700

QUARTZ

HOURS

kPa

PSI

50

75

100

0

0

25

350

700

OFF/

STOP

REMOTE START
DEMAND

OVERCRANK

ENGINE RUNNING

LOW OIL  
PRESSURE

BATTERY  
CHARGER FAIL

A-C

VOLTS

A-C

AMPERES

HERTZ

HIGH ENGINE  
TEMPERATURE

PLANT FAIL/ 
AUXILIARY INPUT

OVERSPEED

MANUAL

START

AUTO

START

OFF

1

Subpanel Dimensions

15 in.  

(xxx mm)

15 in.  

(xxx mm)

15 in.  

(xxx mm)

15 in.  

(xxx mm)

15 in.  

(xxx mm)

15 in.  

(xxx mm)

MGC  
Panel

MOUNTING 

DETAIL 

Nut

MGC
Panel

Wall or 
Pedestal

Screw

Wall or  

Pedestal

Lock  

Washer

Washer

Washer

CAUTION:

To mount the MGC2000 drill and tap the mounting suface, see Mounting hole Pattern, below. Use the

four mounting holes (see mounting details), one on each corner of the bottom of the enclosure, to secure the unit to
the mounting surface by tightening the clamps with a blade type screwdriver. Do not bundle AC and DC wiring
together. It is required to use separate conduit runs and keep apart by at least 2 inches

NEMA 4X ENCLOSURE DIMENSIONS

Summary of Contents for MGC2000

Page 1: ...ded to protect enclosed equipment against splashing seepage falling or hose directed water and severe external condensation AC Meters AC ammeter and an AC voltmeter and a frequency meter are standard...

Page 2: ...m 6 81 in 173 mm kPa PSI 50 75 100 0 0 25 350 700 kPa PSI 50 75 100 0 0 25 350 700 QUARTZ HOURS kPa PSI 50 75 100 0 0 25 350 700 OFF STOP REMOTE START DEMAND OVERCRANK ENGINE RUNNING LOW OIL PRESSURE...

Page 3: ...FF STOP REMOTE START DEMAND OVERCRANK ENGINE RUNNING LOW OIL PRESSURE BATTERY CHARGER FAIL A C VOLTS A C AMPERES HERTZ HIGH ENGINE TEMPERATURE PLANT FAIL AUXILIARY INPUT OVERSPEED MANUAL START AUTO ST...

Page 4: ...protection are provided by either the AC frequency input the magnetic pickup input or the two ground to activate inputs labeled crank disconnect and overspeed AC Voltage AC Voltage is measured via a s...

Page 5: ...M 12 or VM 24 MGC2000 Typical Wiring WARNING Turn the power source off before attempting to perform the wiring operation Do not bundle AC and DC wiring together It is required to use separate conduit...

Page 6: ...C2000E Typical Wiring WARNING Turn the power source off before attempting to perform the wiring operation Do not bundle AC and DC wiring together It is required to use separate conduit runs and keep a...

Page 7: ...esent when the engine is past crank disconnect speed b If the application is using magnetic pickup crank disconnect overspeed make sure that the wiring is correct and that the output is at least 3Vrms...

Page 8: ...ground sender ES2PM 2 wire ungrounded sender EST 1 wire to ground sender ES2T 2 wire ungrounded sender ESDT 2 wire ungrounded sender drives two 2 gages Thru 100 psi 689 kPa 6 89 bar Ranges above 100...

Reviews: