background image

MGC-02030N page 8 of 8

HOW TO ORDER THE MGC2000

Phases

1 =

Single Phase

3 = 

Three Phase

Base Model
MGC2000

=

Mechanical Gages

MGC2000E

=

Electric Gages

Controller

A =

Autostart

M = 

Manual

DC Voltage

12 =

12 VDC

24 = 

24 VDC

AC Voltmeter

150, 300, 600
300D =

300/150 Dual Scale

600D = 

600/300 Dual Scale

Options

AM =

DC Ammeter

(1)

VM = 

DC Voltmeter

(1)

HM = 

Hourmeter

RL = 

Relays

KS = 

Keyswitch

PS = 

Phase Select Switch 

(single phase only)

ES = 

Emergency Stop Switch

4X = 

NEMA 4X Enclosure

QD = 

Quick Disconnect Connectors

HF = 

Hinged Front

MP = 

Magnetic Pickup Sensor

(2)

CT = 

Provide CT’s

(2)

NOTE:

Enter Options prefix in the listed

order, example: 

AMVMRLKS4XMP

AC Ammeter

50, 75, 100, 150, 200, 300, 400, 500, 600, 800, 1000, 1200, 1500, 2000

100D= 

50/100 Dual Scale

300D= 

150/300 Dual Scale

400D= 

200/400 Dual Scale

600D= 

300/600 Dual Scale

800D= 

400/

8

00 Dual Scale

1000D= 

500/1000 Dual Scale

1200D= 

600/1200 Dual Scale

1600D= 

8

00/1600 Dual Scale

2000D= 

1000/2000 Dual Scale

3000D= 

1500/3000 Dual Scale

4000D= 

2000/4000 Dual Scale

5000D= 

250/5000 Dual Scale

MGC2000 1  –  A  –  12 –  300 –  600D –  AMVMRLKS4XMP

Accessories and Replacement Parts

Off-Equipment Mounting Kit

This kit allows off-equipment mounting of the ESPM, ES2PM and ESDPM pressure
senders. Recommended for protection from damaging vibration. Customer supplies
hose and fittings. 

Specify part number 30-00-0213 when ordering.

Sender

Description

ESP

1-wire to ground sender

ES2P

2-wire ungrounded sender

ESDP

2-wire ungrounded sender, drives two (2) gages

ESPM

1-wire to ground sender

††** 

ES2PM

2-wire ungrounded sender

††** 

EST

1-wire to ground sender

*

ES2T

2-wire ungrounded sender

*

ESDT

2-wire ungrounded sender, drives two (2) gages

*

† Thru 100 psi (689 kPa) [6.89 bar].

†† Ranges above 100 psi (689 kPa) [6.89 bar].
** Mounting off-equipment recommended.

Warranty

A limited warranty on materials and workmanship is given with this
FW Murphy product. A copy of the warranty may be viewed or
printed by going to www.fwmurphy.com/support/warranty.htm

CONTROL SYSTEMS & SERVICES DIVISION

P.O. Box 1819; Rosenberg, Texas 77471; USA
+1 281 633 4500  

fax

+1 281 633 4588 

e-mail

[email protected]

MURPHY DE MEXICO, S.A. DE C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje 
San Luis Potosí, S.L.P.; México 78384 
+52 444 8206264  

fax

+52 444 8206336

Villahermosa 52 993 3162117

e-mail

[email protected]

www.murphymex.com.mx

FRANK W. MURPHY, LTD.

Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
+44 1722 410055  

fax

+44 1722 410088  

e-mail

[email protected]

www.fwmurphy.co.uk

MURPHY SWITCH OF CALIFORNIA

41343 12th Street West
Palmdale, California 93551-1442; USA
+1 661 272 4700  

fax

+1 661 947 7570

e-mail

[email protected]

www.murphyswitch.com

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

MACQUARRIE CORPORATION

1620 Hume Highway
Campbellfield, Vic 3061; Australia 
+61 3 9358 5555  

fax

+61 3 9358 5558

e-mail

[email protected] 

FW Murphy 

P.O. Box 470248
Tulsa, Oklahoma 74147 USA 
+1 918 317 4100 

fax

+1 918 317 4266  

e-mail 

[email protected]  

www.fwmurphy.com

R

E

G ISTERE

D

USA–ISO 9001:2000 FM 28221

UK–ISO 9001:2000 FM 29422

Printed in U.S.A.

Summary of Contents for MGC2000

Page 1: ...ded to protect enclosed equipment against splashing seepage falling or hose directed water and severe external condensation AC Meters AC ammeter and an AC voltmeter and a frequency meter are standard...

Page 2: ...m 6 81 in 173 mm kPa PSI 50 75 100 0 0 25 350 700 kPa PSI 50 75 100 0 0 25 350 700 QUARTZ HOURS kPa PSI 50 75 100 0 0 25 350 700 OFF STOP REMOTE START DEMAND OVERCRANK ENGINE RUNNING LOW OIL PRESSURE...

Page 3: ...FF STOP REMOTE START DEMAND OVERCRANK ENGINE RUNNING LOW OIL PRESSURE BATTERY CHARGER FAIL A C VOLTS A C AMPERES HERTZ HIGH ENGINE TEMPERATURE PLANT FAIL AUXILIARY INPUT OVERSPEED MANUAL START AUTO ST...

Page 4: ...protection are provided by either the AC frequency input the magnetic pickup input or the two ground to activate inputs labeled crank disconnect and overspeed AC Voltage AC Voltage is measured via a s...

Page 5: ...M 12 or VM 24 MGC2000 Typical Wiring WARNING Turn the power source off before attempting to perform the wiring operation Do not bundle AC and DC wiring together It is required to use separate conduit...

Page 6: ...C2000E Typical Wiring WARNING Turn the power source off before attempting to perform the wiring operation Do not bundle AC and DC wiring together It is required to use separate conduit runs and keep a...

Page 7: ...esent when the engine is past crank disconnect speed b If the application is using magnetic pickup crank disconnect overspeed make sure that the wiring is correct and that the output is at least 3Vrms...

Page 8: ...ground sender ES2PM 2 wire ungrounded sender EST 1 wire to ground sender ES2T 2 wire ungrounded sender ESDT 2 wire ungrounded sender drives two 2 gages Thru 100 psi 689 kPa 6 89 bar Ranges above 100...