-- 20 --
bt38m2ea
11
MMA WELDING
11.1 Settings --
Tradestig AC 220a
Function
Setting range
In steps of:
Default value
Current
16 -- max. A
2)
1 A
100 A
Hotstart
1)
0 -- 99
1
0
Arc force
1)
0 -- 99
1
5
Drop welding
1)
0=OFF or 1=ON
--
OFF
Weld regulator ArcPlus
t
1)
1=OFF or 0=ON
--
ON
Active panel
OFF or ON
--
ON
Remote control unit
OFF or ON
--
OFF
1)
These functions are hidden functions, see description point 11.3.
2)
The setting range is dependent on the power source used.
11.2 Symbol and Function explanations
VRD (Voltage Reduction Device)
The VRD function ensures that the open--circuit voltage does not exceed 35 V when
welding is not being carried out. This is indicated by a lit VRD LED. The VRD
function is deactivated when the system senses that welding has started.
If the VRD function is activated and open--circuit voltage exceeds the 35 V limit, this
is indicated by an error message (16) appearing in the display and welding cannot
be started whilst the error message is displayed.
NOTE!
The VRD function is not active (LED has gone out) on delivery. Contact an
authorised Murex service technician to activate the function.
MMA welding
MMA welding may also be referred to as welding with coated electrodes. Striking the
arc melts the electrode, and its coating forms protective slag.
During MMA welding, it is possible to weld with reversed polarity.
Select MMA welding
and then press
.
Active panel
Settings are made from the control panel.
Remote control unit
Settings are made from the remote control unit.
Summary of Contents for Tradestig AC 220
Page 26: ...Assembly instructions 26 bt33m11a 26 ...
Page 27: ...R0460 475 074 E090227 P27 27 p ...
Page 28: ...Edition 090227 Diagram 28 bt33e ...
Page 29: ...Edition 090227 29 bt33e ...
Page 30: ...R0460 475 074 E090227 P30 30 p ...
Page 35: ...Tradestig AC 220 Tradestig AC 220a R0460 475 074 E090227 P27 35 bt38mab1 ...
Page 37: ...Tradestig AC 220 Tradestig AC 220a R0460 475 074 E090227 P27 37 bt33sac1 AH 0859 ...
Page 39: ...Tradestig AC 220 Tradestig AC 220a R0460 475 074 E090227 P27 39 bt33sad1 ...
Page 41: ...R0460 475 074 E090227 P41 41 p ...
Page 45: ... 45 notes NOTES ...
Page 46: ...R0460 475 074 E090227 P46 46 paut ...
Page 47: ... 47 notes NOTES ...