-- 19 --
bt38m2ea
To leave hidden functions, press
for 5 seconds.
Tradestig AC 220
Function
Settings
A
= gas pre--flow
0 -- 5 s
b
= slope up
0 -- 9.9
C
= metric/inch
0 = inch, 1 = mm
l
= min current
0 -- 99%
Tradestig AC 220a
Function
Settings
A
= gas pre--flow
0 -- 5 s
b
= micro pulse
0
= OFF;
1
= ON
I
= min current
0 -- 99%
Gas pre--flow
This controls the time during which shielding gas flows before the arc is struck.
Micro pulse
In order to select micro pulse, the machine must be in the pulsed current function
. The value for pulse time and background current is normally 0.01 – 2.50
seconds. By using the micro pulse, the time can go down to 0.001 seconds. When
the micro pulse function is active, times that are shorter than 0.25 seconds are
shown in the display without decimal points.
Min current
Used to set the minimum current for the remote control T1 Foot CAN.
If the max current is 100 A and the min current is to be 50 A, set the concealed
function min current to 50%.
If the max current is 100 A and the min current is to be 90 A, set the min current to
90%.
Summary of Contents for Tradestig AC 220
Page 26: ...Assembly instructions 26 bt33m11a 26 ...
Page 27: ...R0460 475 074 E090227 P27 27 p ...
Page 28: ...Edition 090227 Diagram 28 bt33e ...
Page 29: ...Edition 090227 29 bt33e ...
Page 30: ...R0460 475 074 E090227 P30 30 p ...
Page 35: ...Tradestig AC 220 Tradestig AC 220a R0460 475 074 E090227 P27 35 bt38mab1 ...
Page 37: ...Tradestig AC 220 Tradestig AC 220a R0460 475 074 E090227 P27 37 bt33sac1 AH 0859 ...
Page 39: ...Tradestig AC 220 Tradestig AC 220a R0460 475 074 E090227 P27 39 bt33sad1 ...
Page 41: ...R0460 475 074 E090227 P41 41 p ...
Page 45: ... 45 notes NOTES ...
Page 46: ...R0460 475 074 E090227 P46 46 paut ...
Page 47: ... 47 notes NOTES ...