background image

A481.8 Series

Barrier Free, Wall Mounted Electric Drinking Fountain 

 

A481408S-CUSP / A481408F / A481408S

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

 

LIMITED WARRANTY - UNITED STATES & CANADA

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free 
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) 
months after the date of shipment from the factory, whichever comes first. 

LIMITED EXPORT WARRANTY - 

One year on parts only. 

Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly 
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship 
under normal use for an additional four (4) years from the end of the one (1) year period described above.

COMPLIES 

WITH

7020-100-001 

      

Date: 07/25/18

Test rating conditions are
compliant with ARI 1010.

Federal
Public Law
111-380 
(No Lead)

Member of

 

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

www.murdockmfg.com

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Summary of Contents for A481408S-CUSP

Page 1: ...fixture when finished 2 Please read this entire booklet before beginning the installation 3 Check your installation for compliance with plumbing electrical and other applicable codes Murdock warrants that every cooler bottle filling station packaged water chiller fountain and accessory to be free from defects in material and workmanship under normal use for one 1 year from date of install or eight...

Page 2: ...NPSM Cuspidor 3 8 copper tube Fountain See Figure D Waste is 1 1 4 OD female slip joint connection IMPORTANT 1 Waste P Trap and Water Supply Service Stop Valve to be supplied by others in accordance with local codes GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES 2 DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL STATE LOCAL CODES 3 STOP...

Page 3: ... 12 Secure the Fountain to the Frame Assembly using the supplied 10 32 screws and washers The screws need to pass through the tab and into the frame containing the captive nut Tighten the screws to pull the Fountain flush with the wall 14 Make up 1 1 4 o d p trap waste connection 5 Locate the provided L brackets in relation to the Tabs from the Cuspidor Mark the hole locations remove the Cuspidor ...

Page 4: ...ush in fitting 1 Cut to fit length of PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 2 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET TUBE STOP PUSH IN FITTING 1 4 PE TUBING I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O ...

Page 5: ...m Push button FIGURE C FIGURE B FIGURE D I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A481 8 Page 5 of 6 Revised 07 25 18 7020 100 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmf...

Page 6: ...LOCK WASHER EXTERNAL 20 0279 002 000 8 32 SOCKET CAP BUTTON HD SCREW 3 4 LG 21 7035 108 199 VENTED PANEL 22 7000 021 001 Y STRAINER ASSEMBLY 23 7000 091 001 PUSHBUTTON W HEX ASSY 24 7000 060 000 FLOW REGULATOR CARTRIDGE 0 5 GPM 25 7000 050 001 VALVE ASSEMBLY 7000 012 001 STAINLESS STEEL BUBBLER 7000 410 002 LOW FLOW FLEX BUBBLER GRAY 27 7003 093 001 FLOW RESTRICTOR LOW FLOW BUBBLER ONLY 26 23 24 2...

Reviews: