background image

9.  Make up 1-1/4” o.d. p-trap waste connection.

15.  Thoroughly flush the supply line, connect water supply to the Fountain & Cuspidor.

INSTALLATION:   A481408S & A481408F

2. 

Place the Chiller Unit onto the base pan of the Fountain Frame Assembly.

4. 

Secure the Fountain to the Frame Assembly using the supplied #10-32 screws and washers.

The screws need to pass through the tab and into the frame containing the captive nut. Tighten the 
screws to pull the Fountain flush with the wall.

3.  Install the Air Valve Assembly roughly in position as shown in Figure B. This is supplied for the 

Cuspidor unit only and the installation method will be by others.

7. 

Re-hang the Cuspidor assembly. Secure the Cuspidor to the “L” brackets using the supplied #10-32 

screws & washers. The screws need to pass through the tab and into the “L” brackets containing the 
captive nut. Tighten the screws to pull the Cuspidor flush with the wall.

11.  Securely hang the Fountain Assembly on the top flange of the Frame Assembly making sure that 

the flanges engage.

1. 

Install Mounting Brackets to the bottom and top of the Rough-In opening for the Cuspidor unit.

 

WARNING:

 Mounting Brackets MUST be securely anchored and centered within the opening. See 

Figure B.

2.  Install the Mounting Frame Assembly for the Chilled Fountain. Center the Frame Assembly and

securely install per Rough-In number 7020-000-001. 

4.  Hang the Cuspidor on the upper Mounting Bracket making sure the bracket and flange from 

Cuspidor engage. The Cuspidor must sit flush against the wall.

6.  Install the captive nuts into the “L” brackets as shown in Figure C.

INSTALLATION:   A481408S-CUSP

8.  Install water supply and drain as required per Figure A rough-in dimensions.

10.  Place the Chiller Unit onto the basepan of the Fountain Frame Assembly.

12.  Secure the Fountain to the Frame Assembly using the supplied #10-32 screws and washers.

The screws need to pass through the tab and into the frame containing the captive nut. Tighten the 
screws to pull the Fountain flush with the wall.

14.  Make up 1-1/4” o.d. p-trap waste connection.

5. 

Locate the provided “L” brackets in relation to the Tabs from the Cuspidor. Mark the hole locations, 

remove the Cuspidor and then mount the brackets.

13.  Install water supply and drain as required per Figure A rough-in dimensions.

1. 

Install the Mounting Frame Assembly for the Chilled Fountain. Center the Frame Assembly and

securely install per Rough-In number 7020-000-001.

3. 

Securely hang the Fountain Assembly on the top flange of the Frame Assembly making sure that 

the flanges engage.

7. 

Thoroughly flush the supply line, connect water supply to the Fountain.

1. 

Before assembling bottom covers to the Fountain & or Cuspidor, but after thoroughly flushing the 

supply line and connecting it to the fixture, turn on building water supply and check all connections 
for leaks.

6. 

Make up 1-1/4” o.d. p-trap waste connection.

START UP:

4. 

Install Removable Access Covers to the Fountain & or Cuspidor bottom Mounting Bracket,

install the supplied #8-32 screws & washers from the bottom of the Removable Access Covers.

5. 

Install water supply and drain as required per Figure A rough-in dimensions.

2. 

Air within the Fountain & or Cuspidor or the structure supply piping will cause an irregular outlet 

stream until purged out by incoming water.

3. 

Recheck all water and drain connections with water flowing through system.

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

  

A481.8

Page 3 of 6

Revised: 

07/25/18

7020-100-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Summary of Contents for A481408S-CUSP

Page 1: ...fixture when finished 2 Please read this entire booklet before beginning the installation 3 Check your installation for compliance with plumbing electrical and other applicable codes Murdock warrants that every cooler bottle filling station packaged water chiller fountain and accessory to be free from defects in material and workmanship under normal use for one 1 year from date of install or eight...

Page 2: ...NPSM Cuspidor 3 8 copper tube Fountain See Figure D Waste is 1 1 4 OD female slip joint connection IMPORTANT 1 Waste P Trap and Water Supply Service Stop Valve to be supplied by others in accordance with local codes GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES 2 DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL STATE LOCAL CODES 3 STOP...

Page 3: ... 12 Secure the Fountain to the Frame Assembly using the supplied 10 32 screws and washers The screws need to pass through the tab and into the frame containing the captive nut Tighten the screws to pull the Fountain flush with the wall 14 Make up 1 1 4 o d p trap waste connection 5 Locate the provided L brackets in relation to the Tabs from the Cuspidor Mark the hole locations remove the Cuspidor ...

Page 4: ...ush in fitting 1 Cut to fit length of PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 2 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET TUBE STOP PUSH IN FITTING 1 4 PE TUBING I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O ...

Page 5: ...m Push button FIGURE C FIGURE B FIGURE D I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A481 8 Page 5 of 6 Revised 07 25 18 7020 100 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmf...

Page 6: ...LOCK WASHER EXTERNAL 20 0279 002 000 8 32 SOCKET CAP BUTTON HD SCREW 3 4 LG 21 7035 108 199 VENTED PANEL 22 7000 021 001 Y STRAINER ASSEMBLY 23 7000 091 001 PUSHBUTTON W HEX ASSY 24 7000 060 000 FLOW REGULATOR CARTRIDGE 0 5 GPM 25 7000 050 001 VALVE ASSEMBLY 7000 012 001 STAINLESS STEEL BUBBLER 7000 410 002 LOW FLOW FLEX BUBBLER GRAY 27 7003 093 001 FLOW RESTRICTOR LOW FLOW BUBBLER ONLY 26 23 24 2...

Reviews: