background image

START UP:

1. Before assembling bottom cover to the Cuspidor, but after thoroughly flushing the supply line and 

connecting it to the fixture, turn on building water supply and check all connections for leaks.

2. Air within the Fountain & Cuspidor or the structure supply piping will cause an irregular outlet stream 

until purged out by incoming water.

3. Recheck all water and drain connections with water flowing through system.

4. Install Removable Access Covers to the Fountain & Cuspidor bottom Mounting Bracket, install the 

supplied #8-32 screws from the bottom of the Removable Access Cover.

Repairs must be made with Murdock Manufacturing Company parts only. Please order through your local 

representative or distributor. The phone number to locate your local representative is 1.800.591.9360.

CLEANING & MAINTENANCE GUIDE:

1. Periodically remove access panels and clean out in-line strainer.

2. Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void the Acorn 

warranty.

3. Exterior panels can be cleaned using mild household detergents or warm, soapy water. Extra  care 

must be used cleaning chrome plated items and mirror finished stainless steel. They can scratch easily 
and should only be cleaned using a clean, soft cloth and mild soap with water or a mild glass cleaner. 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A181-CUSP

Page 5 of 9

02/26/16

7020-003-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Summary of Contents for A18040000-CUSP

Page 1: ...l constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each...

Page 2: ...ocal codes Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 2 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 74...

Page 3: ...nts are assembled to the fixture that are not approved by Acorn Engineering Company 5 Fixtures operates within water pressure range of 20 to 105 psig Acorn Engineering Company will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 105 psig A pressure regulator must be furnished by others on supply line if inlet pressure is greater tha...

Page 4: ...ed to pass through the tabs on both units and into the tabs of the lower frame bracket containing the captive nuts Tighten the screws to pull the Fountain Cuspidor flush with the wall 7 Install water supply and drain as required per Figure A rough in dimensions 8 Thoroughly flush the supply lines connect water supply to the Cuspidor 9 Make up 1 1 4 OD P Trap waste connection UPPER MOUNTING BRACKET...

Page 5: ...r to locate your local representative is 1 800 591 9360 CLEANING MAINTENANCE GUIDE 1 Periodically remove access panels and clean out in line strainer 2 Do NOT use harsh chemicals abrasive or petroleum based cleaners Use of these will void the Acorn warranty 3 Exterior panels can be cleaned using mild household detergents or warm soapy water Extra care must be used cleaning chrome plated items and ...

Page 6: ...h in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I ...

Page 7: ... L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 7 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 2 4 3 5 6 9 10 20 11 12 13 14 15 16 19 22 23 24 18 17 8 7 1 21 ...

Page 8: ...GE 0 5 GPM 24 7000 050 001 VALVE ASSEMBLY 1 ITEM PART NUMBER DESCRIPTION 7000 012 001 STAINLESS STEEL BUBBLER ASSEMBLY 7000 099 002 LOW FLOW FLEX BUBBLER GRAY 2 7035 128 199 UPPER MOUNTING BRACKET 3 N A N A 4 N A N A 5 N A N A 6 N A N A 7 N A N A 8 N A N A 9 4926 055 001 GRID STRAINER w CLOSE ELL ASSY 10 0316 020 000 CAPTIVE NUT 11 0331 004 000 10 FLAT WASHER 12 0321 011 000 10 STAR WASHER 13 0116...

Page 9: ...ORT ADA 15 0279 002 000 8 32 SOCKET CAP BUTTON HD SCREW 3 4 LG 16 0322 001 000 8 PLATED STAR LOCK WASHER EXTERNAL 17 7002 125 001 WELDED PUSHBUTTON AIR TROL VALVE ASSY 18 7002 125 002 PUSHBUTTON ASSY AIR VALVE 19 7035 306 001 BRACKET FRAME LWR FTN ONLY ADA 20 7000 415 000 SELF RETAINING J NUT 21 N A N A 22 N A N A 23 N A N A 24 N A N A A181 CUSP Page 9 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 ...