INSTALLATION:
1. Install Mounting Brackets to the bottom and top of the Rough-In opening. WARNING: Mounting
Brackets MUST be securely anchored and centered within the opening. See Figure B.
2. Install the Air Valve Assembly to the rear of the upper support brace as shown in Figure C. This Air
Valve Assembly is supplied for the Cuspidor only.
3. Make sure that the air tube is connected to the pushbutton and valve (Cuspidor only).
4. Install the (4) provided captive nuts into the lower mounting bracket as shown in Figure D.
5. Hang the Fountain & Cuspidor on the Mounting Bracket making sure that bracket and flange from the
Fountain & Cuspidor engage. The Fountain & Cuspidor must sit flush against the wall.
6. Anchor the Fountain & Cuspidor assembly to the bottom Mounting Bracket using the supplied #10-32
screws & washers. The screws need to pass through the tabs on both units and into the tabs of the
lower frame bracket containing the captive nuts. Tighten the screws to pull the Fountain & Cuspidor
flush with the wall.
7. Install water supply and drain as required per Figure A rough-in dimensions.
8. Thoroughly flush the supply lines, connect water supply to the Cuspidor.
9. Make up 1-1/4” OD P-Trap waste connection.
UPPER MOUNTING
BRACKET CENTERED
IN OPENING
FOUNTAIN
ASSEMBLY
CUSPIDOR
ASSEMBLY
REMOVABLE
ACCESS COVER
MOUNTING
TAB
MOUNTING
TAB
CAPTIVE NUT
TYP
LOWER MOUNTING
BRACKET, CENTERED
IN OPENING
AIR VALVE
ASSEMBLY
TO SPRAY NOZZLE
THIS END IS SEALED
½" NPS SUPPLY
TO PUSHBUTTON
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
A181-CUSP
Page 4 of 9
02/26/16
7020-003-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of