background image

INSTALLATION:

1. Install Mounting Brackets to the bottom and top of the Rough-In opening. WARNING: Mounting 

Brackets MUST be securely anchored and centered within the opening. See Figure B.

2. Install the Air Valve Assembly to the rear of the upper support brace as shown in Figure C. This Air 

Valve Assembly is supplied for the Cuspidor only.

3. Make sure that the air tube is connected to the pushbutton and valve (Cuspidor only).

4. Install the (4) provided captive nuts into the lower mounting bracket as shown in Figure D.

5. Hang the Fountain & Cuspidor on the Mounting Bracket making sure that bracket and flange from the 

Fountain & Cuspidor engage. The Fountain & Cuspidor must sit flush against the wall.

6. Anchor the Fountain & Cuspidor assembly to the bottom Mounting Bracket using the supplied #10-32 

screws & washers. The screws need to pass through the tabs on both units and into the tabs of the 
lower frame bracket containing the captive nuts. Tighten the screws to pull the Fountain & Cuspidor 
flush with the wall.

7. Install water supply and drain as required per Figure A rough-in dimensions.

8. Thoroughly flush the supply lines, connect water supply to the Cuspidor.

9. Make up 1-1/4” OD P-Trap waste connection.

UPPER MOUNTING
BRACKET CENTERED
IN OPENING

FOUNTAIN

ASSEMBLY

CUSPIDOR

ASSEMBLY

REMOVABLE

ACCESS COVER

MOUNTING

TAB

MOUNTING

TAB

CAPTIVE NUT
TYP

LOWER MOUNTING
BRACKET, CENTERED
IN OPENING

AIR VALVE
ASSEMBLY

TO SPRAY NOZZLE

THIS END IS SEALED

½" NPS SUPPLY

TO PUSHBUTTON

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A181-CUSP

Page 4 of 9

02/26/16

7020-003-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Summary of Contents for A18040000-CUSP

Page 1: ...l constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each...

Page 2: ...ocal codes Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 2 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 74...

Page 3: ...nts are assembled to the fixture that are not approved by Acorn Engineering Company 5 Fixtures operates within water pressure range of 20 to 105 psig Acorn Engineering Company will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 105 psig A pressure regulator must be furnished by others on supply line if inlet pressure is greater tha...

Page 4: ...ed to pass through the tabs on both units and into the tabs of the lower frame bracket containing the captive nuts Tighten the screws to pull the Fountain Cuspidor flush with the wall 7 Install water supply and drain as required per Figure A rough in dimensions 8 Thoroughly flush the supply lines connect water supply to the Cuspidor 9 Make up 1 1 4 OD P Trap waste connection UPPER MOUNTING BRACKET...

Page 5: ...r to locate your local representative is 1 800 591 9360 CLEANING MAINTENANCE GUIDE 1 Periodically remove access panels and clean out in line strainer 2 Do NOT use harsh chemicals abrasive or petroleum based cleaners Use of these will void the Acorn warranty 3 Exterior panels can be cleaned using mild household detergents or warm soapy water Extra care must be used cleaning chrome plated items and ...

Page 6: ...h in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I ...

Page 7: ... L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 7 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 2 4 3 5 6 9 10 20 11 12 13 14 15 16 19 22 23 24 18 17 8 7 1 21 ...

Page 8: ...GE 0 5 GPM 24 7000 050 001 VALVE ASSEMBLY 1 ITEM PART NUMBER DESCRIPTION 7000 012 001 STAINLESS STEEL BUBBLER ASSEMBLY 7000 099 002 LOW FLOW FLEX BUBBLER GRAY 2 7035 128 199 UPPER MOUNTING BRACKET 3 N A N A 4 N A N A 5 N A N A 6 N A N A 7 N A N A 8 N A N A 9 4926 055 001 GRID STRAINER w CLOSE ELL ASSY 10 0316 020 000 CAPTIVE NUT 11 0331 004 000 10 FLAT WASHER 12 0321 011 000 10 STAR WASHER 13 0116...

Page 9: ...ORT ADA 15 0279 002 000 8 32 SOCKET CAP BUTTON HD SCREW 3 4 LG 16 0322 001 000 8 PLATED STAR LOCK WASHER EXTERNAL 17 7002 125 001 WELDED PUSHBUTTON AIR TROL VALVE ASSY 18 7002 125 002 PUSHBUTTON ASSY AIR VALVE 19 7035 306 001 BRACKET FRAME LWR FTN ONLY ADA 20 7000 415 000 SELF RETAINING J NUT 21 N A N A 22 N A N A 23 N A N A 24 N A N A A181 CUSP Page 9 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 ...