FORM: QM1070
Rev.3, February 2010
Page 6 of 15
Munters Corporation
4215 Legion Dr. Mason, MI 48854-1036 USA
(517) 676-7070 Fax (517) 676-7078
www.munters.us/aerotech
Step 5
Stand (2) cone sections up and fasten with (2) Fastener [B] and [C] in the upper 2
holes.
See Figures 5A and 5B.
Finger tighten only.
Step 6
Stand next cone section up and fasten to previous cone sections as in Step 3. Stand last cone section up
and fasten on both sides be sure to only use the upper 2 holes. Finger tighten only.
Figure 5B
SIDE VIEw OF 2 CONE SECTIONS
¼" x ¾" Wafer
Head Bolt [B]
1
/
4
" Flange Nut [C]
Figure 5A
1
/
4
" x
3
/
4
"
Wafer Head
Bolt [B]
1
/
4
" Flange Nut [C]
¼" x ¾" Wafer
Head Bolt [B]
1
/
4
" Flange Nut [C]
Cone Section