background image

1.GENERAL INFORMATION

2

1.3 RECEIVING THE GOODS 

The air conditioner is delivered in a protective 
packaging and is accompanied by an instruc-
tion manual. This manual is an integral part of 
the air conditioner and should therefore be 
carefully read and preserved. When the air 
conditioner is unpacked, please check that the 
air conditioner and the accessory pack are 
complete and undamaged. 

1.4 HANDLING 

Be fully aware of the weight of the air condi-
tioner before attempting to lift it. Take all nec-
essary precautions to avoid damaging the 
product or causing personal injury
It is advisable to remove the packaging only 
when the air conditioner has been located in 
the point of installation
Carefully remove the adhesive strips posi-
tioned on the air conditioner
Packaging components must be disposed cor-
rectly and not left within reach of children, 
since they are a potential source of danger

1.5 LIST OF ACCESSORIES(P0)

1.FASTENING BRACKET 
2.REMOTE CONTROL 
3.REMOTE CONTROL HOLDER 
4.DRAINAGE PIPE 
5.EXTERNAL GRATING
6.AIR INTAKE PIPE (160 mm.) 
7.AIR DISCHARGE PIPE (150 mm.) 
8.KIT OF SCREWS
9.GRATING FIXING CORD 
10.INSTRUCTION MANUAL 
11.PAPER TEMPLATE FOR WALL DRILLING 
(See page ) 

This product has been manufactured to com-
ply with 2006/95/EC and with amendments 
92/31/EEC and 93/68/EEC  

Waste electrical products should not be 
disposed of with household waste. Please 
recycle where facilities exist. Check with your 
Local Authority or retailer for recycling advice. 

Any batteries used in the remote control 
contain materials, which are hazardous to 
the environment. They must be removed 
from the remote control when they reach 
the end of their life and disposed of 
responsibly. 

1.6 TECHNICAL FEATURES(P1,P2) 

Model

Cooling capacity * W (BTU/h)

Heating capacity * W (BTU/h) 

Rated voltage (V) 

Absorbed power in cooling* (W)

Absorbed current in cooling* (A) 

Absorbed power in heating* (W) 

Absorbed current in heating* (A) 

Air flow (m /h)

Noise level (dB A) 

Dehumidification capacity* (L/24h) 

Optional

 

temperature (remote control)

Fuse (T3.15L)

Refrigerant

Global warmer potential (GWP)

Dimensions H/W/D(cm) 

Weight (Kg) 

WZ 25 

2640 (9000)

2780 (9500)

230 

980 

4,3 

860 

3,8 

400 

47

16,3

18-30°C

250V

R410A 

1750

58/100/23.5

45

STANDARD TEST CONDITIONS -EN 14511-

OPERATING CONDITIONS IN COOLING AND 
DEHUMIDIFICATION MODE

 

-Inside 27°C DB; 19°C WB 
-Outside 35°C DB; 24°C WB 

OPERATING CONDITIONS IN HEATING MODE 

-Outside 7°C DB; 6°C WB 
-Inside 20°C DB

*The above datas could be change in order to improve the performances

ENGLISH

3

Summary of Contents for WZ 25

Page 1: ...o a doppio condotto INSTALLATION AND USER MANUAL MANUALE D USO E INSTALLAZIONE BEFORE INSTALLING AND USING THIS AIR CONDITIONER PLEASE READ ALL INSTRUCCIONS CAREFULL PRIMA DI INSTALLARE ED UTILIZZARE...

Page 2: ...FITTING THE GRATINGS 2 7 FITTING THE AIR CONDITIONER ON BRACKET 3 1 3 2 REMOTE CONTROL FUNCTIONS 3 3 HEATING MODE 3 4 COOLING MODE 3 5 DRY MODE 3 6 FAN MODE 3 7 SLEEPING MODE 3 8 AUTO MODE 3 9 TIMER O...

Page 3: ...in funzione YELLOW LED timer is on LED GIALLO funzione timer inserita BLUE LED nigth mode is on LED BLU funzione sleep inserita P2 Fresh air system Ricambio aria P7 P8 P10 P11 P12 P13 LIFT IT UP HERE...

Page 4: ...in funzione YELLOW LED timer is on LED GIALLO funzione timer inserita BLUE LED nigth mode is on LED BLU funzione sleep inserita P2 Fresh air system Ricambio aria P7 P8 P10 P11 P12 P13 LIFT IT UP HERE...

Page 5: ...urn the air conditioner to an authorised service center for examination and repair to avoid a hazard Do not attempt to repair or adjust any electri cal or mechanical functions on this air condi tioner...

Page 6: ...11 PAPER TEMPLATE FOR WALL DRILLING See page This product has been manufactured to com ply with 2006 95 EC and with amendments 92 31 EEC and 93 68 EEC Waste electrical products should not be disposed...

Page 7: ...evel is used as the air conditioner must be level Follow the installation instructions in full 2 3 DRILLING THE WALL P5 Please note If you are drilling the hole above ground floor level please ensure...

Page 8: ...and humidity infiltration using polyurethane foam and using plaster as finish ing on the inside wall 2 6 FITTING THE GRATINGS P7 P8 P9 P10 To fit the external two gratings please proceed as follows f...

Page 9: ...ATION 5 The appliance shall not be installed the laun dry The appliance must be positioned so that the plug is accessible The appliance shall be installed in accordance with national wiring regulation...

Page 10: ...BUTTON Increase the temperature and time DOWN BUTTON Decrease the temperature and time FAN SPEED BUTTON Set up the fan speed TIMER ON BUTTON Set up the time the air conditioner starts TIMER OFF BUTTO...

Page 11: ...it will run by memory mode 3 4 Cooling mode Press the MODE button set up the mode to cool the air conditioner will run in cooling 3 Press UP or DOWN button to adjust the setting up temperature 4 5 Pre...

Page 12: ...mode 3 6 Fan mode 3 Press UP or DOWN button to adjust the setting up temperature 4 5 Press the FAN SPEED button set up the fan speed is low speed is middle speed is high speed flashing is auto speed F...

Page 13: ...etting button UP and DOWN are disable 4 5 Press the FAN SPEED button set up the fan speed is low speed is middle speed is high speed flashing is auto speed For auto fan the speed is chosen by the diff...

Page 14: ...each time adjusting up 1 hour Press the button each time adjusting up 1 minute When the time is over the air conditioner will be switched off automatically If press this button again before the air co...

Page 15: ...E AND MAINTENANCE 11 3 11 Fresh air system When the fresh air system is open the air conditioner will change the room air automatically in this way new clean and fresh air will intake to the room You...

Page 16: ...hen switched on POSSIBLE SOLUTIONS 1 Wrong setting of the timer Check it 2 Problems on the power supply Call the ser vice center 3 The filter could be dirty Clean it 4 The room temperature is too high...

Page 17: ...7 FISSAGGIO DEL CONDIZIONATORE 3 1 ICONE DEL TELECOMANDO 3 2 FUNZIONI DEL TELECOMANDO 3 3 MODO RISCALDAMENTO 3 4 MODO CONDIZIONAMENTO 3 5 MODO DEUMIDIFICAZIONE 3 6 MODO VENTILAZIONE 3 7 MODO NOTTURNO...

Page 18: ...taggio la frequenza elettrica ed il carico elettrico siano quelli indicati nella etichetta dati tecnici applicata sul condizionatore Il condizionatore non e utilizzabile in luoghi bagnati o molto umid...

Page 19: ...stato costruito secondo le norme di sicurezza della Direttiva EEC 73 23 EEC e 89 336 EEC Le pile del telecomando e l imballo non possono essere smaltiti come rifiuti domestici utilizzate gli appositi...

Page 20: ...lo possono danneggiare Suguite le operazioni di installazione come descritto in questo manuale 2 3 REALIZZAZIONE DEI FORI NEL MURO Figura P5 ATTENZIONE Assicuratevi che esternamente al piano terra in...

Page 21: ...sponsabilita relativa al fissaggio della staffa metallica di supporto del condizionatore 2 5 INSTALLAZIONE DEI TUBI Dopo aver realizzato i due fori da 162mm di diametro occorre inserire i relativi tub...

Page 22: ...siliconica Silicone e anche viti e tasselli in modo da essere sicuri del loro fissaggio e tenuta Mantenete le alette in posizione verticale e ovviamente non utilizzate la corda per il fissaggio 2 7 FI...

Page 23: ...ura che avrete impostato sul telecomando se la temperatura dell ambiente e simile alla temperatura da voi impostata la velocita selezionata automaticamente sara quella piu bassa se la temperatura dell...

Page 24: ...a dello spegnimento 3 4 MODO RAFFREDDAMENTO 19 Sequenza delle operazioni Fare riferimento al punto 3 1 e 3 2 3 USO E MANUTENZIONE Sequenza delle operazioni Fare riferimento al punto 3 1 e 3 2 4 5 2 3...

Page 25: ...tore si avviera secondo l ultimo modo selezionato prima dello spegnimento 4 5 2 3 Premere il tasto MODE e selezionare il modo di funzionamento Ventilazione Premere i tasti UP e DOWN per impostare la t...

Page 26: ...per spegnere il condizionatore 1 Premere il tasto ON OFF ed il condizionatore si avviera secondo l ultimo modo selezionato prima dello spegnimento 4 5 2 3 Premere il tasto MODE e selezionare il modo...

Page 27: ...del ventilatore desiderata 5 Premere il tasto TIMER OFF e mediante il tasto UP selezionare le ore e mediante il tasto DOWN selezionare i minuti trascorso questo tempo che avrete impostato il condizion...

Page 28: ...sistema di rinnovo nella posizione chiusa e di aprirlo solo pochi minuti al giorno per rinnovare l aria della vostra stanza Rinnovo aria Premere per chiudere Premere per aprire Posizione aperta 3 USO...

Page 29: ...mi 3 14 SOLUZIONE PROBLEMI CAUSE DI POSSIBILI PROBLEMI Il condizionatore non funziona Il condizionatore non raffresca il locale in cui e stato installato Il condizionatore emette cattivo odore Dal con...

Page 30: ...B 5 WB 6 interno DB 20 Questo apparecchio non e stato costruito e concepito per l utilizzo dello stesso da parte di persone con ridotte capacita fisiche motorie sensoriali mentali o persone senza espe...

Page 31: ...PAPER TEMPLATE FOR WALL DRILLING 26...

Page 32: ...n Sie bei der Stadtverwaltung beim Entsorgungsamt oder in dem Ge sch ft in dem Sie das Produkt er worben haben Smaltimento delle apparecchia ture obsolete 1 Quando su n prodotto riportato il simbolo d...

Page 33: ......