mundoclima MVD-22GDN1 Service Manual Download Page 3

The 2

nd

 Generation DC Series VRF Indoor Units

 

 

 

4  

201806

 

1

 

Specifications 

Table 1.1:

 

MVD-22(28,36,45)GDN1 specifications

 

Model 

MVD-22GDN1 

MVD-28GDN1 

MVD-36GDN1 

MVD-45GDN1 

Power supply 

1 phase, 220-240V, 50Hz   

Cooling

1

 

Capacity   

kW 

2.2 

2.8 

3.6 

4.5 

kBtu/h 

7.5 

9.6 

12.3 

15.4 

Power input     

28 

28 

30 

40 

Heating

2

 

Capacity 

kW 

2.4 

3.2 

4.0 

5.0 

kBtu/h 

8.2 

10.9 

13.6 

17.1 

Power input 

28 

28 

30 

40 

Fan motor 

Model 

ZKFP-20-8-6 

ZKFP-20-8-6 

ZKSP-58-8-1 

ZKSP-58-8-1 

Type 

DC 

 

Indoor coil 

Number of rows 

Tube pitch × row pitch 

mm 

21×13.37 

Fin spacing 

mm 

1.3 

Fin type 

Hydrophilic aluminum 

Tube OD and type 

mm 

Ф9.53 Inner-groove 

Dimensions (L×H×W) 

mm 

585×315×13.37 

585×315×26.74 

701×315×13.37 

701×315×26.74 

Number of circuits 

Air flow rate

3

 

m

3

/h 

422/411/402/39

3/380/368/356 

417/402/386/37

0/353/338/316 

656/628/591/57

3/544/515/488 

594/563/535/50

7/478/450/424 

Sound pressure level

4

 

dB(A) 

31/30/30/30/29/

29/29 

31/30/30/30/29/

29/29 

33/32/32/31/31/

30/30 

35/34/33/33/32/

31/31 

Sound power level 

dB(A) 

46/45/45/45/44/

44/44 

46/45/45/45/44/

44/44 

48/47/47/46/46/

45/45 

50/49/48/48/47/

46/46 

Unit 

Net dimensions

5

 (WxHxD) 

mm 

835×280×203 

990×315×223 

Packed dimensions (WxHxD) 

mm 

935×385×320 

1085×420×335 

Net/Gross weight   

kg 

8.4/12.1 

9.5/13.1 

11.4/15.5 

12.8/16.9 

Refrigerant type   

R410A 

Throttle Type 

Electronic expansion valve 

Design pressure (H/L)   

MPa 

4.4/2.6

 

Pipe 

connections 

Liquid/Gas pipe 

mm 

Ф6.35/Ф12.7 

Drain pipe 

mm 

OD Φ16

 

Notes: 

1.

 

Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. 

2.

 

Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. 

3.

 

Fan motor speed and air flow rate are from the highest speed to the lowest speed, total 7 rates for each model. 

4.

 

Sound pressure level is from highest level to lowest level, total 7 levels for each model. Sound pressure level is measured in a semi-anechoic chamber. 

5.

 

Unit body dimensions given are the largest external dimensions of the unit, including hanger attachments.

 

 

 

Summary of Contents for MVD-22GDN1

Page 1: ...Wall Mounted Split www mundoclima com Service manual English CL23560 to CL23567 MVD DC2...

Page 2: ...t 1 Specifications 4 2 Dimensions 6 3 Unit Placement 7 4 Piping Diagram 8 5 Wiring Diagram 9 6 Capacity Tables 13 7 Electrical Characteristics 21 8 Sound Levels 22 9 Error codes 24 The 2nd Generation...

Page 3: ...9 33 32 32 31 31 30 30 35 34 33 33 32 31 31 Sound power level dB A 46 45 45 45 44 44 44 46 45 45 45 44 44 44 48 47 47 46 46 45 45 50 49 48 48 47 46 46 Unit Net dimensions 5 WxHxD mm 835 280 203 990 31...

Page 4: ...ound power level dB A 53 52 51 51 50 4 9 49 59 58 57 54 53 5 2 51 59 58 57 54 53 5 2 51 63 61 60 58 56 5 5 53 Unit Net dimensions 5 WxHxD mm 990 315 223 1194 343 262 Packed dimensions WxHxD mm 1085 42...

Page 5: ...eneration DC Series VRF Indoor Units 6 201806 2 Dimensions 2 1 Unit Dimensions Figure 2 1 Wall mounted dimensions unit mm MVD 22GDN1 MVD 28GDN1 MVD 36GDN1 MVD 45GDN1 MVD 56GDN1 MVD 71GDN1 MVD 80GDN1 M...

Page 6: ...as a laundry Units should be installed in positions where y The ceiling is horizontal and is able to bear the unit s weight y There are no obstructions that could impede the airflow into and out of th...

Page 7: ...m Figure 4 1 Wall mounted piping diagram flare nut flare nut T2B gas side motor heat exchanger fan EXV liquid side T2 T1 Legend T1 Indoor ambient temperature sensor T2 Indoor heat exchanger mid point...

Page 8: ...h FM GM CS EEV T2 T2B XP1 5 XS1 5 T1 Indoor fan motor Swing motor Electronic expansion valve Room temp sensor Mid pipe temp sensor Outlet pipe temp sensor Water level switch Connectors CN7 CN30 CN22...

Page 9: ...2B XP1 5 XS1 5 T1 Indoor fan motor Swing motor Electronic expansion valve Room temp sensor Mid pipe temp sensor Outlet pipe temp sensor Water level switch Connectors CN12 CN5 CN7 CN30 21 6 21 6 1 21 6...

Page 10: ...B XP1 5 XS1 5 T1 Indoor fan motor Swing motor Electronic expansion valve Room temp sensor Mid pipe temp sensor Outlet pipe temp sensor Water level switch Connectors Wired controller D1 D2 CN9 21 6 CN1...

Page 11: ...tened at the power supply terminals loose power supply wiring would represent a fire risk After installation servicing or maintenance the electric control box cover should be closed Failing to close t...

Page 12: ...1 5 2 2 1 5 2 2 1 5 2 3 1 3 2 3 1 4 44 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 2 1 5 2 3 1 3 2 3 1 4 46 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 2 1 5 2 3 1 3 2 3 1 4 2 8 10 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1 9...

Page 13: ...2 1 42 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 7 2 4 3 8 2 3 3 8 2 1 44 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 7 2 4 3 8 2 3 3 8 2 1 46 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 7 2 4 3 8 2 3 3 8 2 1 4 5 10 0 3 1...

Page 14: ...3 4 5 8 3 2 6 0 3 1 44 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 7 3 4 5 8 3 2 6 0 3 1 46 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 7 3 7 5 8 3 2 6 0 3 1 7 1 10 0 4 9 3 6 5 8 4 0 6 7 4 3 7 1 4 5 7 5 4 4 8 4 4 5 9...

Page 15: ...0 8 6 4 9 42 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 1 5 3 8 3 5 0 8 6 4 9 44 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 1 5 3 8 3 5 0 8 6 4 9 46 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 1 5 3 8 3 5 0 8 6 4 9 9 0 10...

Page 16: ...9 80 11 00 2 54 2 54 2 40 2 33 2 21 2 02 11 80 13 00 2 64 2 59 2 40 2 33 2 21 2 02 13 70 15 00 2 71 2 59 2 40 2 33 2 21 2 02 2 8 20 19 8 1 79 1 79 1 79 1 79 1 79 1 79 19 18 8 1 92 1 92 1 92 1 92 1 92...

Page 17: ...0 9 00 4 12 4 12 4 00 3 88 3 68 3 36 9 80 11 00 4 24 4 24 4 00 3 88 3 68 3 36 11 80 13 00 4 40 4 32 4 00 3 88 3 68 3 36 13 70 15 00 4 52 4 32 4 00 3 88 3 68 3 36 4 5 20 19 8 2 80 2 80 2 80 2 80 2 80 2...

Page 18: ...0 6 68 6 68 6 30 6 11 5 80 5 29 11 80 13 00 6 93 6 80 6 30 6 11 5 80 5 29 13 70 15 00 7 12 6 80 6 30 6 11 5 80 5 29 7 1 20 19 8 4 48 4 48 4 48 4 48 4 48 4 48 19 18 8 4 80 4 80 4 80 4 80 4 80 4 80 17 1...

Page 19: ...56 7 90 9 00 9 27 9 27 9 00 8 73 8 28 7 56 9 80 11 00 9 54 9 54 9 00 8 73 8 28 7 56 11 80 13 00 9 90 9 72 9 00 8 73 8 28 7 56 13 70 15 00 10 17 9 72 9 00 8 73 8 28 7 56 9 0 20 19 8 5 60 5 04 5 60 5 6...

Page 20: ...220 240 198 264 0 32 15 0 02 0 25 MVD 36GDN1 50 220 240 198 264 0 45 15 0 058 0 36 MVD 45GDN1 50 220 240 198 264 0 47 15 0 058 0 37 MVD 56GDN1 50 220 240 198 264 0 58 15 0 058 0 46 MVD 71GDN1 50 220 2...

Page 21: ...semi anechoic chamber During in situ operation sound pressure levels may be higher as a result of ambient noise Figure 8 1 Wall mounted sound pressure level measurement 8 2 Octave Band Levels Figure...

Page 22: ...z Octave band center frequency Hz 0 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 0 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 0 10 20 30 40 50 60 70 80 63 125 250 500 100...

Page 23: ...xchanger mid point temperature sensor T2 error Indoor heat exchanger outlet temperature sensor T2B error The indoor unit has not beenassigned an address The indoor unit s operating mode conflicts with...

Page 24: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com MVD...

Reviews: