Heating Capacity Table
Table 6.2: Wall mounted heating capacity
Capacity
(kW)
Outdoor air
temperature (°C)
Indoor air temperature (°C DB)
16
18
20
21
22
24
TC
TC
TC
TC
TC
TC
WB
DB
kW
kW
kW
kW
kW
kW
2.2
-20
-19.8
1.34
1.34
1.34
1.34
1.34
1.34
-19
-18.8
1.44
1.44
1.44
1.44
1.44
1.44
-17
-16.7
1.51
1.51
1.51
1.51
1.51
1.51
-15
-14.7
1.56
1.56
1.56
1.56
1.56
1.56
-13.00
-12.60
1.66
1.66
1.66
1.66
1.66
1.66
-11.00
-10.50
1.68
1.70
1.70
1.70
1.70
1.70
-10.00
-9.50 1.75
1.75
1.75
1.75
1.75
1.75
-9.10
-8.50 1.80
1.80
1.80
1.80
1.80
1.80
-7.60
-7.00 1.82
1.82
1.82
1.82
1.82
1.82
-5.60
-5.00 1.90
1.90
1.90
1.90
1.90
1.90
-3.70
-3.00 1.99
1.99
1.99
1.99
1.99
1.99
-0.70
0.00 2.14
2.14
2.14
2.14
2.14
2.02
2.20
3.00 2.26
2.26
2.26
2.26
2.21
2.02
4.10
5.00 2.33
2.33
2.33
2.33
2.21
2.02
6.00 7.00 2.40
2.40
2.40
2.33
2.21
2.02
7.90
9.00 2.47
2.47
2.40
2.33
2.21
2.02
9.80
11.00
2.54
2.54
2.40
2.33
2.21
2.02
11.80
13.00
2.64
2.59
2.40
2.33
2.21
2.02
13.70
15.00
2.71
2.59
2.40
2.33
2.21
2.02
2.8
-20
-19.8
1.79 1.79 1.79 1.79 1.79 1.79
-19
-18.8
1.92 1.92 1.92 1.92 1.92 1.92
-17
-16.7
2.02 2.02 2.02 2.02 2.02 2.02
-15
-14.7
2.02 2.02 2.02 2.02 2.02 2.02
-13.00
-12.60
2.14 2.14 2.14 2.14 2.14 2.14
-11.00
-10.50
2.24 2.24 2.24 2.24 2.24 2.24
-10.00
-9.50
2.34 2.34 2.34 2.34 2.34 2.34
-9.10
-8.50
2.40 2.40 2.40 2.40 2.40 2.40
-7.60
-7.00
2.43 2.43 2.43 2.43 2.43 2.43
-5.60
-5.00
2.53 2.53 2.53 2.53 2.53 2.53
-3.70
-3.00
2.66 2.66 2.66 2.66 2.66 2.66
-0.70
0.00
2.85 2.85 2.85 2.85 2.85 2.69
2.20
3.00
3.01 3.01 3.01 3.01 2.94 2.69
4.10
5.00
3.10 3.10 3.10 3.10 2.94 2.69
6.00 7.00 3.20
3.20
3.20 3.10 2.94 2.69
7.90
9.00
3.30 3.30 3.20 3.10 2.94 2.69
9.80
11.00
3.39 3.39 3.20 3.10 2.94 2.69
11.80
13.00
3.52 3.46 3.20 3.10 2.94 2.69
13.70
15.00
3.62 3.46 3.20 3.10 2.94 2.69
Abbreviations:
TC: Total capacity
Notes:
1.
Shaded cells indicate rating condition.
Table continued on next page …