Wall mounted FCU DC

air filter 

net of clear air 

mesh enclosure of clear air 

1. Dismantle the air filter.   
 
2. Clean the air filter  

The air filter can prevent the dust or other particulate from 
going inside. In case of blockage of the filter, the working 
efficiency of the air conditioner may greatly decrease . 
 
Therefore, the filter must be cleaned once two weeks during 
long time usage. 
 
Clean the air filter with vacuum cleaner or water. 
 
a.The air-in side should face up when using vacuum  
    cleaner. (Refer to 

Fig.6-2

b.The air-in side should face down when using clean water.  
    (Refer to 

Fig.6-3

 
If the dust accumulation is too heavy, please use soft bursh and 
natural detergent to clean it and dry in the cool place. 

Fig.6-1

Fig.6-3

Do not dry out the air filter under direct sunshine or with fire. 
 

 

CAUTION 

3. Re-install the air filter. 
 
4. Install and close the air-in grill in the reverse orders of step  
   1 and 2 and connect the control box cables to the  corre 
   sponding terminators of the main body.   

7.    FOLLOWING SYMPTOMS ARE NOT AIR 

       CONDITIONER TROUBLES 

Symptom 1: The system does not operate 

Symptom 2: Change into the fan mode during cooling   
                      mode 

The air conditioner does not start immediately after the ON/OFF 
button on the romote controller is pressed.  
If the operation lamp lights, the system is in normal condition.To 
prevent overloading of the compressor motor, the air 
conditioner starts 3 minutes  after  it  is turned ON. 

 
If the operation lamp and the "PRE-DEF indicator(cooling and 
heating type) or fan only indicator(cooling only type)" light, it 
means you choose the heating model, When just starting, if the 
compressor has not started, the indoor unit  appears "anti cold 
wind" protection because of its overlow outlet temperature. 

In order to prevent the indoor evaporator frosting, the system 
will change into fan mode automatically, restore to the cooling 
mode after soon. 
 
When the room temperature drops to the set temperature, the 
compressor goes off and the indoor unit changes to fan mode; 
when the temperature rises up, the compressor starts again. It 
is same in the heating mode. 

Symptom 3: White mist comes out of a unit 

Symptom 4: Noise of air conditioners cooling  

When humidity is high during cooling operation If the interior of 
an indoor unit is extremely contaminated,the temperature 
distribution inside a room becomes uneven. It is necessary to 
clean the interior of the indoor unit.Ask your dealer for details on 
cleaning the unit.This operation requires a qualified service 
person. 

 

When the system is changed over to heating operation after 
defrost operation Moisture generated by defrost becomes 
steam and is exhausted.   

A continuous low "shah" sound is heard when the system is in 
cooling operation or at a stop.  
When the drain pump (optional accessories) is in operation,this 
noise is heard. 
 
A "pishi-pishi" squeaking sound is heard when the system stops 
after heating operation.  
Expansion and contraction of plastic parts caused by 
temperature change make this noise.  

Symptom 5: Dust comes out of the unit  

Symptom 6: The units can give off odours 

When the unit is used for the first time in a long time.  
This is because dust has gotten into the unit. 

When the tone of operating noise changes.  
This noise is caused by the change of frequency. 

The unit can absorb the smell of rooms, furniture, cigarettes, 
etc., and then emit it again.  

Fig.6-2

16

Summary of Contents for MUP-W7

Page 1: ...English CL04315 to CL04318 Wall Mounted FCU DC www mundoclima com www mundoclima com MUP W7 Installation and Owner s manual and Information requirements...

Page 2: ...be used for hosehold use The power supply must be SINGLE PHASE one phase L and one neutral N with his grounded power GND switch Any breach of these specifications involve a breach of the warranty con...

Page 3: ...entative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find manyanswers to common problems in the chart of troubleshooting tips If you revi...

Page 4: ...e the single outlet with other electrical appliances Otherwise it will cause fire or electrical shock Be sure to be in conformity with the local national and international laws and regulations Read PR...

Page 5: ...til w including iring and piping the air conditioner is done While following the instructions in this installation manual install drain piping in order to ensure proper drainage and insulate piping in...

Page 6: ...ve and negative poles are right positions when loading batteries This manual is subject to changes due to technological improvement without further notices Cautions on remote controller installation R...

Page 7: ...ntal and its structure can endure the weight of the indoor unit The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room The c...

Page 8: ...en the outdoor unit and bend and arrange the pipe carefully Be careful not to let the drain hose slack Insulate both of the auxiliary piping 43 Indoor unit outline Connective pipe 2 Drilling a hole De...

Page 9: ...Unit from side to side up and down to check if it is hooked securely Because the condensed water from rear of the indoor unit is gathered in Pond Box and is piped out of room Do not put anything else...

Page 10: ...Fig 7 2 NOTE 7 1 Terminal Board Diagram Please refer to the indoor unit wiring diagram for the wiring The air conditioners can connect with Central Control Monitor CCM Before operation please wiring c...

Page 11: ...ative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find manyanswers to common problems in the chart of troubleshooting tips If you review...

Page 12: ...l Air inlet Air outlet Inlet pipe Return pipe Drain pipe 1 2 3 4 5 Bottom plate Remote controller Faceplate Display panel Horizontal air deflector 1 2 3 4 5 3 Display panel Infrared signal receiver Op...

Page 13: ...d by yourself may result in a water leakage electric shock and fire Ask your dealer for improvement repair and maintenance Incomplete improvement repair and maintenance may result in a water leakage e...

Page 14: ...is product as unsor ted municipal waste Collection of such waste sepa rately for special treatment is necessary Do not dispose of electrical appliances as unsorted municipal waste use separate collect...

Page 15: ...h to wipe the indoor unit and remote controller A wet cloth may be used to clean the indoor unit if it is very dirty Never use a damp cloth on the remote controller Do not use a chemically treted dust...

Page 16: ...eating model When just starting if the compressor has not started the indoor unit appears anti cold wind protection because of its overlow outlet temperature In order to prevent the indoor evaporator...

Page 17: ...nate all dirties and make air smooth Close doors and windows Make curtains in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Symptoms Causes Unit does not start A...

Page 18: ...nd then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the...

Page 19: ...REMOTE CONTROLLER Please read this manual carefully before installing and using the unit 19...

Page 20: ...or or the like objects will prevent the remote signal from being received by air conditioner Do not get the interior of remote controller wet It is forbidden to expose it to direct sunlight or locate...

Page 21: ...urrent setting and reset remote controller LOCK inner located Press this button with a needle of 1mm to lock or unlock the current setting OK Used to confirm the time setting and modification COOL HEA...

Page 22: ...adjust the time 3 Keep pressing this button the time will increase by 0 5 hour When the set time exceeds 10 hours pressing the button will increase the time by 1 hour 4 0 5s after setting remote contr...

Page 23: ...essing TIMER button will increase the time by 1 hour Adjust the TIMER OFF to be 0 00 then can cancel the TIMER OFF 2 1 Model and specification 2 2 Buttons and their functions Decrease the set temp Kee...

Page 24: ...OFF TIMER ON FOLLOWME TEMP FAN SPEED FAN SPEED FOLLOW ME FOLLOW ME SLEEP MODE ON OFF Lock Timer ON OFF Running mode Temperature Fan speed Transmitting display Follow Me Transmitting display The icon...

Page 25: ...tting temperature of 26 C 26 C green function Lock function Fig 5 5 Fig 5 6 Auto heat recycling mode function CAUTION 5 4 Other functions operations only available when the indoor unit has correspondi...

Page 26: ...ON only can set timing OFF under the remote controller is OFF only can set timing ON Precautions Curtain door or the like objects will prevent the remote signal from being received by air conditioner...

Page 27: ...Wall mounted FCU DC Q Q Q and and cancel timer on and timer off Q state 27 Remote controller...

Page 28: ...Wall mounted FCU DC turn on or turn off th e auto sw ing function room temperature read from th e local sensor and 28 Remote controller...

Page 29: ...1 0 2 45 0 9 1 0 1 0 00 5 0 1 2 3 45 0 1 3 45 6 0 1 7 33 45 8 1 0 9 1 0 2 45 0 9 1 0 1 0 00 5 0 1 3 45 0 1 3 45 6 0 1 7 233 45 8 1 0 9 1 0 45 0 9 1 0 1 0 00 5 2 0 1 3 45 0 1 2 3 45 6 0 1 7 33 45 8 1 0...

Page 30: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...

Reviews: