OMNI-SYSTEM
CONFIGURATION MENU
DUMP SETTINGS:
Dump Down Cylinder: This setting determines if the
cylinder is a single acting or double acting design.
Dump PSI: Adjust this setting to control the
downside relief pressure. Keep in mind that the
downside relief is disabled when the cylinder is set
for single acting.
Dump Down Min/Max: Adjust this setting to control
the down speed of the dump cylinder. The min%
allows the deadband to be removed from the joystick
operation. The max% controls the cylinder speed
when the joystick if fully deflected or using the
panel buttons.
Dump Up Min/Max: Adjust this setting to control the
up speed of the dump cylinder. The min% allows the
deadband to be removed from the joystick operation.
The max% controls the cylinder speed when the
joystick is fully deflected or using the panel buttons.
CYLINDER - DUMP
DUMP
CYL
PSI
DOWN
SA
0600
DUMP
MIN
MAX
DOWN
045%
065%
DUMP
MIN
MAX
UP
015%
065%