SNOW & ICE DIVISION
PAGE 10
CONFIGURATION MENU
DATALOGGING MENU:
Clear System Totals: Depress the spinner knob to
clear the system datalog totals.
GLOBAL EQUIPMENT
SETTINGS:
Unloader - Type: Rotate the liquid knob to select the
appropriate unloader type. Selections include open
(gear pump), closed (piston pump), none (alternate
piston pump setup).
Unloader – Rel: Select to adjust the Main Relief
Pressure. The system can be set to a maximum of
3,000 PSI. Deadhead the plow angle to observe the
main relief pressure.
Road Temp Offset: This adjustment allows the road
temperature sensor to be tuned if the current reading
is slightly inaccurate.
1. To check the accuracy of the road
temperature, insert a cup of ice water under
the IR sensor. The temperature should read
approximately 32 F.
2. If the temperature is off, use the spinner knob
to offset the temperature sensor to correct the
displayed value.
* The air temperature cannot be adjusted. Keep
in mind that the air temperature can be slower
to adjust since it is a function of the sensor
housing.
Groundspeed Calibration: The groundspeed
calibration can be set using two different methods.
Only one method is required to sync the speedometer.
Option 1 – MPH Cal: If the pulse count is known
for the chassis, simply use the liquid and spinner
knobs to directly enter the value.
Option 2 – MPH Sync: Drive the truck and
maintain 20 MPH while pressing the spinner
button. This will auto populate the “Groundspeed
Cal” text box.
DATALOGGING
CLEAR SYSTEM TOTALS
GLOBAL EQUIPMENT
UNLOADER
TYPE
REL
OPEN
2200
ROAD TEMP
OFFSET 0
MPH
PUL/MI
CAL
00001
MPH
SYNC 0