4.2. 

General installation 

 

Any hardware used must be compatible with any other used material to avoid galvanic corrosion. Defects 
caused by corrosions void the warranty. 

It is not recommended to use modules with different configurations (grounding, wiring) in the same 
system. 

Excessive cables must be organized or fixed in an adequate way, e.g. attached to the mounting structure 
by using non-metallic cable ties. Solar cables, connectors and junction boxes should not be exposed to 
water exposure, and snow, and rain or water submersion for a long period of time (IP65/67/68). 

For applications requiring high operating voltage several modules can be connected in series to form a 
string of modules; the system voltage is then equal to the sum of the voltage of each module. 

For applications requiring high operating currents several strings of modules can be connected in parallel; 
the system current is then equal to the sum of the current of each string of modules. The maximum 
system voltage is 600 volts ,1000 volts or 1500 volts depending on the product family DC according to 
standards. 

The maximum number of series connected modules depends on system design, the type of inverter used 
and environmental conditions. 

Based on the maximum series fuse rating of module and local electrical installation code, always make 
sure München Solar PV modules are assembled with the appropriate string fuse for circuit protection. 

There is no specific limitation on the number of modules that can be connected in parallel, the number of 
modules is determined by system design parameters such as current or power output. To prevent the 
cables and the connectors from overheating, the cross section of the cables and the capacity of the  

connectors must be selected to suit the maximum system short circuit current. The recommended cable 
is PV wire with a cross section of at least 4mm2. 

Caution: do not secure the cables too tight. Any cable damage caused by cable management system is 
not covered under München Solar's warranty. 

Always refer to the cable manufacturer's bending radius which includes the radius just behind the 
connectors. 

When designing large modules arrays connected to a single inverter, always take into account the 
resulting isolation resistance (Riso), which decrease increasing the number of modules in the array. A too 
low Riso can results in inverter faults. Please refer to local regulations to determine the system wires size, 
type and temperature. 

München Solar modules are supplied with connectors used for system electrical connections. The 
recommended connectors are 

TL-CABLE01S connectors, Amphenol H4 connectors, Multi Contact MC4 connectors etc. München Solar 

Summary of Contents for MSMD M10-60 Series

Page 1: ...M nchen Solar Installation Manual M nchen Energieprodukte GmbH www muenchen energieprodukte de...

Page 2: ...y 3 1 4 Fire Safety 4 2 Product Identification 5 3 Mechanical installation 6 3 1 Selecting the location 6 3 2 General Installation 6 3 3 Installation methods 7 3 4 Attachment guidelines 8 4 Electrical...

Page 3: ...t light energy to direct current electrical energy They are designed for outdoor use Modules can be ground mounted mounted on rooftops The proper design of support structures lies within the responsib...

Page 4: ...eriod of time always cover the modules and ensure that the glass faces down on a soft flat surface to prevent water from collecting inside the module and causing damage to exposed connectors 1 3 Insta...

Page 5: ...ctors to connect modules to form a string or connect to another device Removing the connectors will void the warranty 1 4 Fire Safety Consult your local authority for guidelines and requirements for b...

Page 6: ...o 1000 1500 volts while other UL products are 600 volts Check your nameplate or contact your local representative for details 2 Barcode each individual module has a unique serial number The serial num...

Page 7: ...ys use a tested and certified mounting structure approved for your system design In regions with heavy snowfall in winter select the height of the mounting system so that the lowest edge of the module...

Page 8: ...maximum permissible loads and are not subject to excessive forces due to the thermal expansion of thesupport structures Never allow modules overlap or exceeds the rooftop Refertothefollowinginstallati...

Page 9: ...t of 1600 Pa 0 232psi 2500 Pa 0 363 psi and 3600 Pa 0 522 psi respectively under UL 1703 standard The diagrams in the tables below are designed for illustration purpose For each installation modules c...

Page 10: ...0 Pa safety factor 1 5 M2 30 series M3 30 series M3 60 series M6 60 series Test load positive 5400 Pa negative 2400 Pa Design load positive 3600 Pa negative 1600 Pa safety factor 1 5 M2 30 series M3 3...

Page 11: ...Pa negative 3800 Pa Design load positive 3600 Pa negative 2533Pa safety factor 1 5 M2 30 series M3 30 series M3 60 series M6 60 series M6 72 series M10 60 series M10 72 series Clamp zone A 1 4 long f...

Page 12: ...sitive 5400 Pa negative 3800 Pa Design load positive 3600 Pa negative 2533Pa safety factor 1 5 M6 60 series M6 72 series M10 60 series M10 72 series Clamp zone A0 1 4 short frame length 50 mm A1 100 m...

Page 13: ...gative 3800 Pa Design load positive 3600 Pa negative 2533Pa safety factor 1 5 M2 30 series M3 30 series M3 60 series M6 60 series M6 72 series M10 60 series M10 72 series Attentions The module clamps...

Page 14: ...7V01 13 The mounting holes reserved for tracker mounting system with special accessories The length of module is over 2 meters whose load value with tracker needsto be confirmed by module supplier res...

Page 15: ...connected to the PV output Voltages are additive when modules are connected in series and modules currents are additive when Modules are connected in parallel as illustrated in Figure 1 Modules with...

Page 16: ...e maximum number of modules that can be connected in series within a string for the specific project must be calculated based on the actual local temperature If there is reverse current exceeding the...

Page 17: ...maximum series fuse rating of module and local electrical installation code always make sure M nchen Solar PV modules are assembled with the appropriate string fuse for circuit protection There is no...

Page 18: ...allation is finished and after connection to the grid please do a professional hand over to the owner including an installation protocol is required Provide a clear documentation of the system to the...

Page 19: ...F to bond solar modules to module mounting brackets grounding part is tested to UL467 3 Use WEEB DPF to bond solar modules to module mounting brackets grounding part is tested to UL467 Recommend faste...

Page 20: ...tions every six months to verify that they are clean secure undamaged and free of corrosion Or else the warranty may be voided In the event of a ground fault condition NEVER wash or spray modules with...

Reviews: