Multitel SDTA-01 User Manual Download Page 5

TABLE OF CONTENTS 

 

 

CONTROL SHEET ............................................... 4

 

1. General Information ............................................ 5

 

1.1 Description .................................................................................................... 5

 

1.2 Content ......................................................................................................... 6

 

2. Specifications ..................................................... 7

 

2.1 Electrical Specifications .................................................................................. 7

 

2.2 Environmental Specifications ......................................................................... 7

 

2.3 Mechanical Specifications .............................................................................. 7

 

3. Operation ......................................................... 8

 

3.1 General .......................................................................................................... 8

 

3.2 Analog Channel Setup ................................................................................... 8

 

4. Installation ........................................................ 9

 

4.1 Tools and Equipment ..................................................................................... 9

 

4.2 Mounting the  System ..................................................................................... 9

 

4.3 Cables and Connections ............................................................................... 10

 

4.3.1 General Information .................................................................. 11

 

4.3.2 Connecting the Primary to 110 VAC .......................................... 11

 

4.3.3 Connecting the Primary to 220 VAC .......................................... 12

 

4.3.4 Connecting the Secondary Circuit .............................................. 14

 

4.3.5 Definition of Connectors ............................................................ 14

 

5. Maintenance ..................................................... 15

 

5.1 Calibration ................................................................................................... 15

 

5.1.1 Mirador or Site Manager ............................................................ 15

 

5.1.2 MXP2 188 .................................................................................. 15

 

5.2 Troubleshooting ........................................................................................... 16

 

6. Contacting Multitel ............................................ 18

 

Index ................................................................. 19

 

 

TABLES: 

 

Table 1 - Configuration of the analog channel ...................................................... 8

 

Table 2 – Wiring of the primary for 110 VCA ..................................................... 11

 

Table 3 – Wiring of the primary for 220 VCA ..................................................... 13

 

Table 4 – Wiring of the secondary circuit to the SDTA-01 .................................. 14

 

Table 5 - Definition of J3 ................................................................................... 14

 

Table 6 - Definition of J8 ................................................................................... 14

 

 

FIGURES: 

 

Figure 1 - Physical appearance of the SDTA-01 .................................................... 5

 

Figure 2 Wall installation of the SDTA-01 ......................................................... 10

 

Figure 3  Connecting 110 VCA to the SDTA-01 ................................................. 12

 

Figure 4  Connecting 220 VCA to the SDTA-01 ................................................. 13

 

 

3

 

Summary of Contents for SDTA-01

Page 1: ...SDTA 01 Step Down Transformer Adapter Version 2 1 User s Manual...

Page 2: ......

Page 3: ...in writing by MULTITEL INC the holder of this document shall 1 Keep all information contained herein confidential and shall protect same in whole or in part from disclosure and dissemination to all t...

Page 4: ...2...

Page 5: ...12 4 3 4 Connecting the Secondary Circuit 14 4 3 5 Definition of Connectors 14 5 Maintenance 15 5 1 Calibration 15 5 1 1 Mirador or Site Manager 15 5 1 2 MXP2 188 15 5 2 Troubleshooting 16 6 Contacti...

Page 6: ...INATOR 1 0 93 12 10 First English Issue P P 1 1 94 02 17 Corrections S Vaughan 1 2 94 05 19 Certification update P Poulin 2 0 01 07 30 Technical and English review Upgrade to a new format Johanne Lava...

Page 7: ...ON 1 GENERAL INFORMATION 1 1 Description The SDTA 01 is an interface accessory that converts AC voltage into AC voltage signal compatible with MULTITEL power monitoring systems MPMS Figure 1 Physical...

Page 8: ...ter 2 Specifications contains the electrical environmental and mechanical technical specifications for the SDTA 01 Chapter 3 Operation describes the mode of operation and SDTA 01 s scale configuration...

Page 9: ...230 VAC Output signal 17 VAC at nominal input voltage max 28 VAC 2 2 Environmental Specifications Operating Temperature 0 to 50 C 32 to 122 F Humidity 0 to 90 non condensing Storage Temperature 40 to...

Page 10: ...Channel Setup The MPMS analog channel needs the proper scaling factor according to the AC voltage range see following table Please refer to the user manual of your MPMS for a complete description of s...

Page 11: ...r BX cable 14 2 Belden cable 9305 or 20 AWG stranded NOTE unpack and verify with the Material list that all the material is received and in good condition 4 2 Mounting the System The SDTA 01 is instal...

Page 12: ...SDTA 01 4 3 Cables and Connections This section provides the general installation procedures and demonstrates how to interconnect and put into service an SDTA 01 NOTE you can find connectors J1 to J8...

Page 13: ...ease refer to their own user manuals 4 3 2 Connecting the Primary to 110 VAC Refer to Table 2 and Figure 3 for more detail 1 Remove the two screws holding the SDTA s cover in place using a screwdriver...

Page 14: ...Connecting the Primary to 220 VAC Refer to Table 3 and Figure 4 for more detail 1 Remove the two screws holding the SDTA s cover in place using a screwdriver 2 With a BX 14 2 cable wire two 20A AC ma...

Page 15: ...BINSTALLATION Table 3 Wiring of the primary for 220 VCA ELECTRICAL BOX J3 BLACK BREAKER AC1 WHITE BREAKER AC2 N FRAME GROUND Linked by the cable s metal shielding Figure 4 Connecting 220 VCA to the SD...

Page 16: ...he output cable away from the primary circuit Pin 1 of J8 is linked to the positive analog channel of the MULTITEL power monitoring system and pin 2 of J8 is linked to the negative analog channel Crim...

Page 17: ...the wire from the connector associated with the analog channel 3 Short circuit the 2 wires of the analog channel 4 Enter the CALIBRATION command 5 Choose 1 for Analog Channels 6 Choose the card numbe...

Page 18: ...voltmeter reading and follow the instructions NOTE for the universal module it is not necessary to short the input in order to adjust to zero since the module does that automatically 5 2 Troubleshoot...

Page 19: ...age present at the SDTA 01 inputs Verify JP1 JP2 and JP3 setting for the same MPMS you are installing optional The wiring is not according to specification in the SDTA 01 connector s definition The SD...

Page 20: ...ays eager to answer any question you might have about the SDTA 01 Simply telephone us write to us or visit our Internet site where you will find FAQ s for SDTA 01 2500 Jean Perrin Street Qu bec Qc G2C...

Page 21: ...the secondary circuit 14 Contacting MULTITEL 18 Content 6 D Definition of the connectors 14 Description 5 E Electrical specifications 7 G General 8 General information 5 11 content 6 description 5 I...

Reviews: