MultiModemBA User Guide
2.
You then select 1 or 2. With 1, the modem goes back into data mode and with 2, the modem
responds with the following:
Password>
3.
Enter your Setup Password, and if the code is correct the modem responds with:
OK
You can now use any AT commands of the modem being remotely configured as if they were
being entered locally. You cannot change the setup of the LOGIN Password until you enter the
proper LOGIN Password.
4.
When you are done entering AT commands and you want to exit, type
AT0 and hit RETURN.
The modem responds with:
1. DATA Mode
2. COMMAND Mode
5.
Enter a 1 to go back on-line with your computer, or enter 2 and the correct password to talk to
your modem.
6.4
Remote Configuration and Callback Security AT Commands
When you have callback security enabled for the modem, anyone trying to connect with the modem
will be required to furnish a password. The
#CBN command allows you to enter passwords for each
of the 30 memory locations used for callback security. The length of each password can be up to 10
characters, but must be at least 6 characters. Any ASCII character can be used.
The format for this command is
AT#CBNyyxxxxxxxx<CR> with xxxxxxxx representing the
password and
yy being the memory location (0-29). Each callback password (xxxxxxxx) must start
with a non-numeric character.
Callback Security Enable/Disable
#DB
The purpose of this command is to enable or disable (default setting) your modem's callback security
option. Once this command is executed, you modem will undergo some significant changes. For
example, the phone number memory locations (N0 through N9) will be used for passwords and
phone numbers. In other words, you will not be able to dial from memory or use the DTR dialing
feature.
You can turn on callback security by typing AT#DB1 or AT#DB2 and pressing <CR>. If you want to
engage both remote and local password security, use the
#DB1 command. This sets up the modem
so you have to provide passwords to dial into the modem and to dial out. For remote password
security only, use the
#DB2 command. This allows the local operator to dial out without providing the
LOGIN and SETUP passwords. Use
#DB3 when calling another modem with callback security active.
Change LOGIN Password
#I
The default LOGIN password for your modem is
"MULTI-TECH". If you choose to activate callback
security, you should change the LOGIN password using this command in the following format:
AT#Ixxxxxxxxxx<CR> (where
xxxxxxxxxxxxxxxx is the current LOGIN password). Your modem will
respond with
"OK", indicating that you can enter the new LOGIN password as follows:
AT#I=yyyyyyyyyy<CR>
You can select any combination of keyboard characters (upper/lower case sensitive) between six
and ten characters long.
Summary of Contents for BA-Series
Page 1: ...BA Series Intelligent Data Fax Modem User Guide ...
Page 5: ...Chapter 1 Introduction and Description ...
Page 13: ...Chapter 2 Installation and Connection ...
Page 17: ...Chapter 3 Software Configuration and Modem Basics ...
Page 21: ...Chapter 4 Command Mode ...
Page 49: ...Chapter 5 S Registers ...
Page 57: ...Chapter 6 Callback Security and Remote Configuration ...
Page 65: ...Chapter 7 DIP Switch Settings ...
Page 74: ...Chapter 8 Warranty Service and Tech Support ...
Page 78: ...Appendixes ...