59
Chapter 6 - Callback Security and Remote Configuration
Table 6-1. Modem LOGIN, Setup and Remote Escape Code Procedures
To change your modem’s LOGIN Password and Setup Password:
Step
Procedure
Note: Passwords are upper/lower case sensitive. The case you enter here is the case that must be
used at Log-In.
1.
Type
AT#IMULTI-TECH and hit RETURN. Your modem will respond with:
OK (if the LOGIN Password is wrong, the modem’s response is ERROR)
2.
Type
AT#SMODEMSETUP and hit RETURN. Your modem will respond with the following:
OK (or ERROR if wrong Setup Password)
Note: At this point you can change the LOGIN Password and Setup Password.
3.
Type
AT#I=xxxxxxxxxx (with any keyboard characters used, minimum 6 maximum 10) and hit
RETURN. Your modem responds with:
OK
4.
Type
AT#S=yyyyyyyyyy (with keyboard characters used, minimum 6 maximum 10) and hit
RETURN. Your modem responds with:
OK
To change your Remote Configuration feature status:
5.
If you want Remote Configuration off, set S-Register S13 to 0 (zero). Refer to Chapter 6 for
details on how to set S-Register values.
6.
If you want Remote Configuration on and wish to change the Remote Escape Character, change
the S-Register S13 value. If you leave it at the default value, decimal 37 (% sign) will be your
modem’s remote escape character.
To turn your modem's Callback Security feature on and off:
7.
If you want Callback Security with both remote and local password security, enter
AT#DB1 and
hit RETURN. You must turn on Callback Security to be able to enter dial back phone numbers.
8.
If you want Callback Security on with just remote password security, enter
AT#DB2 and hit
RETURN. You must turn on Callback Security to be able to enter dial back phone numbers. If
you want to use your modem to call another modem that is also set for Callback, you must enter
AT#DB3 before you dial.
Note: this is for your modem if you are set for #DB1 or #DB2.
Once you have disconnected from that call, your modem will go back to its original setting.
9.
If you want Callback Security turned off, type
AT#DB0 and hit RETURN.
To set parity of the password/message prompt:
10. The parity default value for your modem is no parity (
AT#P0). If your modem's prompt messages
use even parity, enter
AT#P2 and hit RETURN. For odd parity, enter AT#P1 and hit RETURN.
11. Enter the
&W0 command and hit RETURN to store parameters and S-Register values in RAM.
Summary of Contents for BA-Series
Page 1: ...BA Series Intelligent Data Fax Modem User Guide ...
Page 5: ...Chapter 1 Introduction and Description ...
Page 13: ...Chapter 2 Installation and Connection ...
Page 17: ...Chapter 3 Software Configuration and Modem Basics ...
Page 21: ...Chapter 4 Command Mode ...
Page 49: ...Chapter 5 S Registers ...
Page 57: ...Chapter 6 Callback Security and Remote Configuration ...
Page 65: ...Chapter 7 DIP Switch Settings ...
Page 74: ...Chapter 8 Warranty Service and Tech Support ...
Page 78: ...Appendixes ...