Working

1). When pulse comes from sensor, upper display indicates Decrement in COUNT in

Instrument. Lower Display indicates Set Count Value .

2). For Manual Mode, set time = 00.0 sec. and for Auto Reset Mode, set time = 00.1 to

99.9 sec.

3). When process value = Zero, Relay energies. Relay remains ON for Auto Reset

Time Relay turns off after completion of time. If time is set at 00.0 sec. then relay
remains ON until

key is pressed.

4). If there is a power failure the last reading is stored in the memory and Counter starts

resume counting from the last stored value, when power ON.

5). To restart Counting or to Reset press

key. Upper display will show set point and

the counting will restart.

6). The proximity switch give pulse to counter every time the metal on the roller is sensed.

Press

key to save & exit

Change by

key.

To shows over count Yes/ No

Change by

key.

Speed Of count

SLOW: MAX RPM 500
MEDIUM: MAX RPM 5000
FAST: MAX RPM 15000

RESET









RESET

Press

key

SET

SET

ENT

ENT