background image

JetTouch

®

Workstation

Operating Guide

852 Feehanville Drive
Mt. Prospect, IL 60056
800 786 5528

cumminsallison.com

© 2013 Cummins-Allison Corp. All rights reserved. 

All trademarks remain the property of their respective owners.

Cummins-Allison Corp. has endeavored to make the content of this document accurate and complete, but this information is 
subject to correction or change without prior notice. 

This manual contains proprietary information of Cummins-Allison Corp. It is intended solely for the  
information and use of parties authorized by Cummins Allison to maintain the equipment described 
herein. Such proprietary information may not be used, reproduced, or disclosed to any other parties for 
any other purpose without express written permission of Cummins Allison.

 

022-7811-00 Rev. A

Summary of Contents for JetTouch

Page 1: ...ment accurate and complete but this information is subject to correction or change without prior notice This manual contains proprietary information of Cummins Allison Corp It is intended solely for the information and use of parties authorized by Cummins Allison to maintain the equipment described herein Such proprietary information may not be used reproduced or disclosed to any other parties for...

Page 2: ...air clearance from ventilation holes on the PC terminal Air must flow freely around the terminal at all times Power supply The customer must provide a single phase dedicated power line that meets the machine s power rating s Use a properly grounded circuit breaker in compliance with applicable local electrical code Diagrams This section outlines features of the JetTouch workstation PC Terminal Por...

Page 3: ...ces the risk of hard drive failure The battery is located on the bottom of the unit as shown at right LED Indicator The LED indicator below the touch screen communicates important information about the machine s power status Indicator statuses are described in the following chart Lithium battery installed Only replace battery with battery of same type Follow local environmental protection laws and...

Page 4: ...ess to End the current batch Transfer batch totals to the day total register Reset batch totals for the next transaction END OF SUB BATCH Press to End the current sub batch Transfer sub batch totals to the current batch total register Reset sub batch totals for the next transaction Prepare for processing another sub batch or ending the current batch START Press to Start the transaction Prompt the ...

Page 5: ... completed sub batch MENU Press to prompt the OPERATOR MENU or SUPERVISOR MENU Credentials entered on the SYSTEM SIGN ON screen determine which screen appears Status Bar No Name Description 1 Supervisor operator ID This screen name is associated with the operator or supervisor currently signed onto the system 2 Current system date This is the system date which is controlled by the operating system...

Page 6: ...o end a batch 1 Complete the transaction for the current batch 2 Press END OF BATCH on the main processing screen 3 Start a new batch The current sub batch cannot be ended until data is entered on the ACCOUNT INFORMATION screen If the text on the END OF SUBBATCH button is gray then account information has not been entered Enter account information to proceed The process of ending a batch cannot be...

Page 7: ... and receive data 2 Press EXIT to return to the main processing screen Pressing CANCEL exits the END OF DAY screen without executing end of day procedures and prompts the SUPERVISOR MENU STOP Supervisor Menu Description PASSWORD MAINTENANCE Press PASSWORD MAINTENANCE to prompt the PASSWORD MAINTENANCE screen below This screen is used to add change or delete IDs and passwords There are two user gro...

Page 8: ... target directory Supervisor Menu Description EXPORT LIST2 Continued When a file with the same name already exists in the target directory the following screen appears The previously exported file may not have been removed from the target directory Do one of the following Press APPEND to add information from the current file to the existing file in the target directory Press OVERWRITE to overwrite...

Page 9: ...rget directory the following screen appears The previously exported file may not have been removed from the target directory Do one of the following Press APPEND to add information from the current file to the existing file in the target directory Press OVERWRITE to overwrite the existing file in the target directory with the new data Press CANCEL to return to SUPERVISOR MENU without exporting dat...

Page 10: ... The number of characters entered into a field exceeded the limit Action Press OK and enter a valid number Stopping Conditions and Recovery Steps The following conditions cause the JetTouch workstation to stop and require action by the user Daily Cleaning Procedures for the PC Terminal Recommended Cleaning Materials Simple Green the recommended cleaning agent can be an eye irritant Avoid eye conta...

Reviews: