Video Grabber User Manual - v. 1.19 (FW 1.29)
46
5.4.2.
staGeneral (subsection 2)
In the following table only
OBJECTNUMBER
part of the identifier (OID) is listed.
OBJECTNUMBER Name
Access
Type
Description
1
uptime
read-only Counter Number of seconds since the
Video Grabber was started
2
uptimeTotal
read-only Counter Total number of seconds since
the Video Grabber was first
started
3
healthTempCpu
read-only Integer
CPU temperature in °C
4
healthTempPcb
read-only Integer
PCB temperature in °C
5
healthPower1
read-only Integer
Power 1 status:
0 – down
1 – up
6
healthPower2
read-only Integer
Power 2 status:
0 – down
1 – up
7
lastResetReason
read-only string
Reason of the last reset of the
device:
user – device was restarted by
the user (e.g. using web-
interface)
power – device was restarted
due to the disconnection of
power
8
healthDpPower
read-only Integer
Dual power status:
0 – down (one power is down)
1 – up (both powers are up)
Example:
The OID for uptime is
1.3.6.1.4.1.46236.1.2.2.1.0
as the OID is constructed in the
following way:
VIDEO GRABBER . SECTION . SUBSECTION . OBJECTNUMBER .
1.3.6.1.4.1.46236.1 .
2
.
2
.
1
. 0