Specifications

Warranty*

John Deere Engine

12 months from date of purchase and unlimited hours or 24 months
from date of purchase with 2000 hours (whichever ocurs first).

*Refer to the express written, Engine warranty sheet for additional coverage
information.

Generator

24 months from date of purchase or 2000 hours (whichever occurs
first).

*Refer to the express written, one-year limited warranty sheet for additional
information.

Trailer

12 months excluding normal wear items.

Generator Specifications

Design

Revolving field, Self-ventilated,

Drip-proof, Single bearing

No. of Poles

4-pole

Excitation

Brushless with AVR

Standby Output

158 KW (198 KVA)

Prime Output

144 KW (180 KVA)

Generator RPM

1800

Voltage - 3 phase

208, 220, 240, 415, 440, 480V Reconnectable

Voltage - single phase

120, 127, 139, 240, 254, 277V Adjustable

Armature Connection

Star with neutral

Voltage Regulation

(No load to full load)

±0.5%

Power Factor

0.8

Frequency

60 Hz

Frequency Regulation:

No Load to Full Load

Isochronous under varying loads from

no load to 100% rated load

Frequency Regulation:

Steady State

±0.25% of mean value for constant loads

from no load to full load

Insulation

Class F

Sound Level dB(A)
Full load at 23 feet

72

Engine  Specifications

Make/Model

John Deere / 6068HF485

Emissions

EPA Tier 3 Certified

Starting System

Electric

Design

4-cycle, Watercooled, Direct injection,

Turbocharged, Air to air intercooled

Displacement

6800 cc

No. cylinders

6

Bore x Stroke (mm)

106 x 127

Gross Engine Power Output

315 hp (235 kW)

BMEP

304 psi (2094 kPa)

Piston Speed

1134 ft/min (5.76 m/s)

Compression Ratio

17 : 1

Engine Speed

1800 rpm

Overspeed Limit

2100 rpm

Oil capacity gallons (liters)

8.19 (31.0)

Battery

12V 128 Ah

Fuel  System

Recommended Fuel

ASTM-D975-No.1 or No. 2-D

Maximum Fuel Flow (per hour)

22.7 gal. (85.9 L)

Maximum Inlet Restriction (Hg)

5.9 in. (150 mm)

Fuel Tank Capacity

100 gal. (380 L)

Fuel Consumption

gph

lph

full load

11.4

43.0

75% load

9.0

34.1

50% load

6.6

25.1

25% load

4.3

16.2

Cooling System

Fan Load

21.5 hp (16 kW)

Coolant Capacity (with radiator)

6.3 gal. (24 L)

Coolant Flow Rate

70 gal. (265 L)

Heat Rejection to Coolant

5404 Btu (5.7 MJ)

Heat Radiated to Room

3264 Btu (3.44 MJ)

Maximum Coolant Friction Head

2 psi (13.8 kPa)

Maximum Coolant Static Head

21 ft. (6.4)

Ambient Temperature Rating

104°F (40°C)

Air

Combustion Air

619 cfm (17.5 m

3

/min)

Maximum Air Cleaner Restriction

25.0 in H

2

0 (6.25 kPa)

Alternator Cooling Air

1459 cfm (41.3 m

3

/min)

Radiator Cooling Air

8120 cfm (230 m

3

/min)

Exhaust System

Gas Flow (full load)

1371 cfm (38.8 m3/min)

Gas Temperature

905°F (485°C)

Maximum Back Pressure

40.0 in. H

2

0 (10 kPa)

Amperage

Rated Voltage

Maximum Amps

1Ø 120 Volt

400 Amps (4 wire)

1Ø 240 Volt

200 Amps (4 wire)

3Ø 240 Volt

433 Amps

3Ø 480 Volt

216 Amps

Main Line Circuit Breaker Rating

500 Amps

Over Current Relay Trip Set Point

216 Amps

Generator is not intended for use in enclosed areas or where free flow of air is restricted.

Backfeed to a utility system can cause electrocution and/or property damage.  Do not
connect to any building’s electrical system except through an approved device.

                         

Specifications are subject to change without notice.