Maintenance
Section 4
4-6
Part Number 020002115
10/11
5. Draw rinse water through system until clean water is
dispensed. Most beverage valves allow the syrup
side to be manually activated by depressing the
syrup pallet.
6. Connect Bucket 2 to system.
7. Draw detergent solution through system until
solution is dispensed.
8. Repeat steps 2-7 until all syrup circuits contain
detergent solution.
9. Allow detergent solution to remain in the system for
5 minutes.
10. Connect Bucket 3 to system.
11. Draw sanitizing solution through system until
solution is dispensed.
12. Repeat step 11 until all syrup circuits contain
sanitizer solution.
13. Allow sanitizer solution to remain in system for 15
minutes.
14. Remove nozzles and diffusers from beverage
valves.
15. Scrub nozzles, diffusers and all removable valve
parts (except electrical parts) with a plastic brush or
a soft cloth and the detergent solution.
16. Soak nozzles, diffusers and removable valve parts
(except electrical parts) in sanitizer for 15 minutes.
17. Replace nozzles, diffusers and valve parts.
18. Connect Bucket 1 to system.
19. Draw rinse water through system until no presence
of sanitizer is detected.
20. Attach syrup connectors to BIB’s.
21. Draw syrup through system until only syrup is
dispensed.
22. Discard first 2 drinks.
Preventive Maintenance
Preventative maintenance is a vital part of keeping your
dispenser in top condition. Following the guidelines
below will assist you in continued trouble-free operation
of your unit.
1. Conduct daily maintenance of the machine.
2. Perform monthly maintenance of the machine.
3. Perform periodic maintenance and sanitizing of
beverage system.
4. Do not overfill the dispenser bin with ice.
5. Do not allow the dispenser to sit for prolonged
periods of non use with ice in the bin.
6. Most ice dispenser service problems are caused by
low usage of the ice dispenser.
7. Do not allow ice to remain in the bin more than a day
in order to prevent ice from freezing together and/or
stagnant ice.
Possible excess ice storage reasons:
•
Storage capacity exceeds daily requirements.
•
Low demand during the off season.
•
Dispenser oversized with future growth in mind.
Lower ice storage to meet one day’s needs. If you
manually fill ice, fill only with the appropriate amount of
ice. Fill the dispenser with fresh ice each morning. Do
not fill the dispenser at night just before shut down. Ice
cubes can freeze together if not dispensed.
Contact MBE at 1-800-367-4233 for more information
about our ProActive Maintenance Program.
Shipping, Storage and Relocation
!
Caution
Before shipping, storing, or relocating this unit,
syrup systems must be sanitized. After sanitizing, all
liquids (sanitizing solution and water) must be
purged from the unit. A freezing environment
causes residual sanitizing solution or water
remaining inside the unit to freeze, resulting in
damage to internal components.
Summary of Contents for S250M 10
Page 29: ......