118
Par
t Number
Temperature Set To 36º
No
Refer To Control
Board Diagnostics
Temperature Set
Too High?
Reset Temperature
Adjusting Temperature
Starts Compressor?
Check Thermistor Mounting &
Refer To Thermistor Diagnostics
Yes
No
No
Yes
Compressor Starts
After 15 Minutes
No
Yes
No
Yes
Verify:
Compressor Overload is Closed
Start Components Function
Condenser Fan Motor Functions
Voltage Must Be Within 10% Of Nameplate At
Compressor Startup
Compressor Starts
After 3 Minutes?
Compressor On?
No
Compressor Anti Short Cycle Delay Is 3 Minutes
Yes
Yes
Defrost Cycle Was Initiated:
Determine Cause Of 3 Hour
Continuous Compressor Run Time
Clean The Condenser Coil
Check Clearances
High Ambient
Yes
Summary of Contents for MB-8-1
Page 22: ...22 Part Number STH034 3 12 This Page Intentionally Left Blank...
Page 24: ...24 Part Number STH034 3 12 Dimensions A 26 00 66 cm B 32 82 83 cm A B Elevation View...
Page 26: ...26 Part Number STH034 3 12 G 32 82 83 cm J 39 09 99 cm I 36 15 92 cm G I J Side View...
Page 96: ...96 Part Number STH034 3 12 This Page Intentionally Left Blank...
Page 158: ...158 Part Number STH034 3 12 This Page Intentionally Left Blank...
Page 164: ...164 Part Number STH034 3 12 This Page Intentionally Left Blank...
Page 169: ...Part Number STH034 3 12 169 VERSION 1 ICE MACHINE R404A REFRIGERANT ICE MACHINE WIRING DIAGRAM...
Page 170: ...170 Part Number STH034 3 12 VERSION 1 ICE MACHINE R404A REFRIGERANT ICE MACHINE LOGIC DIAGRAM...
Page 175: ...Part Number STH034 3 12 175 VERSION 2 ICE MACHINE R290 REFRIGERANT ICE MAKER WIRING DIAGRAM...
Page 177: ......