Muller HYDRO-GUARD 200 Series Operating Instructions Manual Download Page 5

5

NOTE:  
- Pr or - key when running 
in MANUAL FLUSH mode will modify 
FLUSH TIME for that station.
- Pressing the button when a 
station is running in manual 
watering will stop flush on the 
current station and advance to the 
next station.
- Pressing the button when a 
station is running In manual 
watering will stop the flush on the 
current station and revert to the 
previous station.

Turn System Off 

To turn off controller, press 

RETURN/ENTER

 key button 

until icon resembling water 
spray and 

OFF

 is displayed on 

screen. To return controller to 
auto programming mode, press 

RETURN/ENTER

 key. The controller 

will immediately return to auto 
programming mode and will display 
time and battery life indicator. 

NODE Quick Check 

This circuit diagnostic procedure 
can quickly identify "shorts" 
commonly caused by faulty 
solenoids or when bare common 
wire touches a bare station control 
wire. To initiate 

NODE

 

Quick Check

 

procedure: 

1. 

From Idle Mode, press and hold 

+, -, LEFT ARROW, and RIGHT 
ARROW

 keys.

2. 

Display will show all segments. 

Release keys.

3. 

Press + key to initiate 

NODE

 

Quick Check

 test.

4. 

Controller will then activate 

flushing unit for 1 second to verify 
operation.

Battery Life Indicator 

Remaining battery life can be 
estimated from the battery life 
indicator shown on display. The 
NODE can operate using either a 

Setting Flushing Days 
1.

 Press 

RETURN/ENTER

 key until 

CALENDAR

 icon is displayed. The 

program letter (A, B, or C) will be 
displayed. Arrows point at specific 
days of week in which flushing will 
occur.

2. 

Press 

LEFT

 or 

RIGHT ARROW

 to 

scroll though days.

3.

 Press 

+

 key to activate that day 

for program displayed, or 

-

 key to 

cancel watering for that day. The 
arrow will show on flushing days for 
active program.

4.

 Press 

PRG

 key to set days to 

flush for a different program, if 
desired. 

5.

 Press 

RETURN/ENTER

 key 

to proceed to next programming 
function, or allow controller to  
return to Idle mode.

Manual Flushing 

Manual flushing allows user to test 
the Hydro-Guard® unit or a program 
for a specified run time.
Make sure controller is in Idle 
Mode.

1.

 Press and hold 

RIGHT ARROW

 

until 

HAND

 icon is displayed. The 

station number (always #1) will 
be displayed in lower left side of 
display along with 

RUN TIME

.

2.

 Use the 

LEFT

 or 

RIGHT ARROW

 

to select #1 station if not already 
displayed, and 

+

 or 

-

 key to set 

manual flushing time. 

3. 

To manually activate a program, 

press 

PRG

 key. Program letter (A, 

B, or C) will show on screen. If a 
different program is needed, press 

PRG

 key until desired program is 

displayed.

4. 

To stop 

MANUAL FLUSHING

 

cycle press - key until time is 
reduced to zero.

  

5. 

Press 

RETURN/ENTER

 key 

to proceed to next programming 
function, or allow controller to return 
to idle mode. 

 

single 9-volt battery or using two 
9-volt batteries. Using two 9-volt 
batteries will yield approximately 
twice the battery life of a single 
9-volt battery. The battery life 
indicator chart below shows an 
estimate of remaining battery life.

Full: 

100-60% remaining battery

 

life

 

Med: 

60-25% remaining battery life 

Low: 

25-0% remaining battery life

 

Replace battery immediately!

Resetting Controller 

Resetting controller will erase 
current program data and restart 
controller. A reset does not, 
however, delete a program saved to 
permanent memory using the Easy 
Retrieve Memory feature to save a 
preferred program.

1. 

From Idle Mode, press and hold

 -, 

RIGHT ARROW

, and 

PRG

 keys.

2. 

After two seconds screen will go 

blank. Continue to hold keys.

3. 

12:00 will flash on display. 

Release keys.

4. 

The controller may show a 

countdown from 10 to 1 on  
display, and then 12:00 am will 
be shown flashing when reset is 
complete. The controller can now  
be reprogrammed.

Programming Unit 

200 SERIES WARM CLIMATE HIGH-PROFILE DIRECT DISCHARGE UNIT

Summary of Contents for HYDRO-GUARD 200 Series

Page 1: ...elieved 4 Always use all necessary safety equipment and follow all recommended procedures when installing operating and maintaining the Hydro Guard Automatic Flushing Device 5 Replace worn or defective parts with OEM parts and check your battery twice a year 6 Operate the Hydro Guard Automatic Flushing Device only when fully installed and correctly assembled 7 It is recommended that a pressure red...

Page 2: ...Hydro Guard Unit into place pressing it firmly into the noncompacted bedding material until it is fully seated 4 Connect the utility s water system to the Hydro Guard Unit by means of the 2 threaded connection Ensure that Unit is level before beginning the backfilling operation to the installation of the device the drainage patterns for the intended installation location should be reviewed The dra...

Page 3: ...nch the application on your Smartphone or Tablet 4 Associate the controller with your phone by tapping the Add a Controller button 5 The app will now ask what type of Bluetooth device you would like to add 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT Programming Unit PROGRAMMING HYDRO GUARD UNIT FOR OPERATION Discharged water flushed from the Hydro Guard Unit must be routed away from...

Page 4: ...ray and connect the battery connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring a proper seal is created Also The NODE has non volatile memory which allows battery replacement without losing program information Idle Mode Waking Up Normall...

Page 5: ...lush for a different program if desired 5 Press RETURN ENTER key to proceed to next programming function or allow controller to return to Idle mode Manual Flushing Manual flushing allows user to test the Hydro Guard unit or a program for a specified run time Make sure controller is in Idle Mode 1 Press and hold RIGHT ARROW until HAND icon is displayed The station number always 1 will be displayed ...

Page 6: ... Warm Climate Direct Discharge Unit The following is a brief overview and introduction to Hydro Guard Options Sample Station Included A standard feature on the 200 Series Warm Climate High Profile Direct Discharge Unit is the sample port which allows Hydro Guard s Portable Sample Valve Part HG S 1167 to attach to the sample port to obtain a sample Slip off the sanitary blue cap attach the quick co...

Page 7: ...allow for required service and maintenance If disassembly is necessary please follow the directions below Always close the curb stop before working on the unit 200 Series Warm Climate Removal of Internal Compo nents FOR AIR GAP MODEL 1 Shut off water supply and secure isolation valve 2 Remove the housing cover by tilting the housing upward while lifting slightly on its end Once the retaining pin l...

Page 8: ...enoid will not close Try this Correction Run a manual flush for 1 minute Change batteries Check connections for corrosion breaks or lack of connection Check the adapters and solenoid for debris Run the electrical systems check Refer to valve troubleshooting for possible corrective measures Check the water pressure at the unit The pressure must be in the operating range of the solenoid and programm...

Page 9: ...Gap 6 Receiver Pipe By Others Dechlorination System BlueTooth or NODE Controller Integrated Program Mueller Curb Box Optional Mueller 2 Curb Stop Optional Quick Disconnect Supply Line By Others Quick Connect HG S116B Portable Sample Valve Optional SCH 80 PVC Internal Piping Brass Optional 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT ...

Page 10: ...ipe Release Light Green Enclosure ID PART NUMBER DESCRIPTION 1 HG 15100 LG Enclosure 2 HG DECHLORHG2 HP Dechlorination Chamber 3 HG 123100 2 Composite Control Valve 4 546589 NODE Controller Assembly Programming Option 5 HG S302 BlueTooth Controller Programming Option 6 546767 200 Series Warm High Profile Replacement Piping Assembly 7 HG 15113 P Key Enclosure Security 8 HG S294 HG2 TCV Assembly 1 2...

Page 11: ...11 Notes 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT ...

Page 12: ...ter Products Inc All Rights Reserved The trademarks logos and service marks displayed in this document are the property of Mueller Water Products Inc its affiliates or other third parties Products marked with a section symbol are subject to patents or patent applications For details visit www mwppat com These products are intended for use in potable water applications Please contact your Mueller S...

Reviews: