Programming Unit 

Programming 

The NODE has the capability to 
hold 3 programs (A, B, C) and 4 
start times per program. When 
programming, flashing portion of 
display can be changed by pressing 

+

 or 

-

 keys. To change something 

not flashing, press 

LEFT 

or 

RIGHT 

ARROWS

 until desired item is 

flashing.

Setting Date/Time 
1. 

Press 

RETURN/ENTER

 key until 

CLOCK

 icon is displayed.

2. 

All 4 digits will be displayed 

representing the year. Use 

+

 or 

-

 

keys to change year. Press 

RIGHT

 

ARROW

 key to proceed to setting 

month.

3. 

All 4 digits will be displayed 

with two digits on left flashing 
representing the MONTH. Use 

+

  

or 

-

 key to change month. Press 

RIGHT ARROW

 key to proceed lo 

setting 

DAY

.

4. 

Only two digits on right will 

be flashing, representing the 

DAY

. Press 

+

 or 

-

 key to change 

day. Press 

RIGHT ARROW

 key to 

proceed to changing 

TIME

.

5.

 The 

AM/PM/24

 time setting 

is shown flashing. Press 

+

 or 

-

 key 

to change to AM, PM, or 24:hour 
time. Press 

RIGHT ARROW

 key to 

proceed to setting the 

HOUR

.

6.

 All 4 numbers are shown with 

two numbers on the left flashing, 
representing the 

HOUR

. Press 

+

 

or 

-

 key to change the hour. Press 

RIGHT ARROW

 key to proceed to 

setting 

MINUTES

.

7.

 All 4 numbers are shown with 

two numbers on right flashing, 
representing 

MINUTES

. Press 

+

  

or 

-

 key to change minutes. 

(Pressing 

RIGHT ARROW

 key will 

return to 

YEAR

 setting at step #2.)

8. 

Press 

RETURN/ENTER

 key 

to proceed to next programming 
function, or allow controller to return 
to idle mode.

200 Series Warm Climate Built-In: 
(Integrated)

NODE Programming Instructions
Batteries

The NODE uses standard 9-volt 
alkaline batteries to operate the 
control valve and program the 
controller. The controller can 
operate with one or two batteries 
installed. Under normal conditions, 
potential life is 1 year for a single 
battery. 

Battery Installation
1.

 Unscrew rear body of the 

NODE to gain access to battery 
compartment.

2. 

Insert battery/batteries into 

battery tray and connect the battery 
connector to controller.

3.

 Make sure no water is inside 

battery compartment.

4.

 Screw the NODE rear body back 

onto front half. 

NOTE: Make sure that seal marker 
on rear half of the NODE lines  
up with front half, ensuring a proper 
seal is created. Also, The NODE has 
non-volatile memory, which allows 
battery replacement without losing 
program information. 

Idle Mode - Waking Up

Normally the NODE display shows 
time and day, day of week, and 
battery life Indicator. During a short 
period of inactivity the display will 
shut off to retain battery power 
Pressing any key will wake up the 
NODE to the Idle Mode.

Run Mode 

When controller is operating a 
program, items shown on display 
will include station number (always 
"1"), program letter (A, B, or C), 
remaining runtime, and a blinking 
Rotor icon.

Setting Flush Sequence Start 
Times 
1. 

Press 

RETURN/ENTER

 key until 

CLOCK

 icon is displayed.

2.

 The 

START TIME

 will be 

displayed flashing, along with the 
program letter (A, B, or C) and start 
time number (1, 2, 3, or 4) in the 
upper left of the display. Up to 4 
different start times can be set for 
each program.

3.

 Use 

+

 or 

-

 key to change 

START 

TIME

 for program displayed. Each 

press of key will change start time 
in 15-minute increments.

4.

 Press 

RIGHT ARROW

 key to 

add an additional 

START TIME

 to 

program displayed. The start time 
number Is shown in upper left 
corner of display.

5.

 Press 

PRG

 key to add 

START 

TIME

 to a different program.

6.

 Press 

RETURN/ENTER

 key 

to proceed to next programming 
function, or allow controller to  
return to Idle mode.

Setting Flush Duration Times  
1. 

Press 

RETURN/ENTER

 key until 

HOURGLASS

 icon is displayed. 

RUN 

TIME

 will be displayed flashing. 

Also shown is program letter (A, B, 
or C) and active station# (always 
#1- all other stations not used) on 
lower left side of display.

2. 

Press 

+

 or 

-

 key to change 

station 

RUN TIME

 from 1 minute  

to 6 hours.

3. 

Press 

PRG

 key to add a 

RUN 

TIME

 to another program.

4. 

Press 

RETURN/ENTER

 key 

to proceed to next programming 
function, or allow controller to  
return to Idle mode.

200 SERIES WARM CLIMATE HIGH-PROFILE DIRECT DISCHARGE UNIT

Summary of Contents for HYDRO-GUARD 200 Series

Page 1: ...elieved 4 Always use all necessary safety equipment and follow all recommended procedures when installing operating and maintaining the Hydro Guard Automatic Flushing Device 5 Replace worn or defective parts with OEM parts and check your battery twice a year 6 Operate the Hydro Guard Automatic Flushing Device only when fully installed and correctly assembled 7 It is recommended that a pressure red...

Page 2: ...Hydro Guard Unit into place pressing it firmly into the noncompacted bedding material until it is fully seated 4 Connect the utility s water system to the Hydro Guard Unit by means of the 2 threaded connection Ensure that Unit is level before beginning the backfilling operation to the installation of the device the drainage patterns for the intended installation location should be reviewed The dra...

Page 3: ...nch the application on your Smartphone or Tablet 4 Associate the controller with your phone by tapping the Add a Controller button 5 The app will now ask what type of Bluetooth device you would like to add 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT Programming Unit PROGRAMMING HYDRO GUARD UNIT FOR OPERATION Discharged water flushed from the Hydro Guard Unit must be routed away from...

Page 4: ...ray and connect the battery connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring a proper seal is created Also The NODE has non volatile memory which allows battery replacement without losing program information Idle Mode Waking Up Normall...

Page 5: ...lush for a different program if desired 5 Press RETURN ENTER key to proceed to next programming function or allow controller to return to Idle mode Manual Flushing Manual flushing allows user to test the Hydro Guard unit or a program for a specified run time Make sure controller is in Idle Mode 1 Press and hold RIGHT ARROW until HAND icon is displayed The station number always 1 will be displayed ...

Page 6: ... Warm Climate Direct Discharge Unit The following is a brief overview and introduction to Hydro Guard Options Sample Station Included A standard feature on the 200 Series Warm Climate High Profile Direct Discharge Unit is the sample port which allows Hydro Guard s Portable Sample Valve Part HG S 1167 to attach to the sample port to obtain a sample Slip off the sanitary blue cap attach the quick co...

Page 7: ...allow for required service and maintenance If disassembly is necessary please follow the directions below Always close the curb stop before working on the unit 200 Series Warm Climate Removal of Internal Compo nents FOR AIR GAP MODEL 1 Shut off water supply and secure isolation valve 2 Remove the housing cover by tilting the housing upward while lifting slightly on its end Once the retaining pin l...

Page 8: ...enoid will not close Try this Correction Run a manual flush for 1 minute Change batteries Check connections for corrosion breaks or lack of connection Check the adapters and solenoid for debris Run the electrical systems check Refer to valve troubleshooting for possible corrective measures Check the water pressure at the unit The pressure must be in the operating range of the solenoid and programm...

Page 9: ...Gap 6 Receiver Pipe By Others Dechlorination System BlueTooth or NODE Controller Integrated Program Mueller Curb Box Optional Mueller 2 Curb Stop Optional Quick Disconnect Supply Line By Others Quick Connect HG S116B Portable Sample Valve Optional SCH 80 PVC Internal Piping Brass Optional 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT ...

Page 10: ...ipe Release Light Green Enclosure ID PART NUMBER DESCRIPTION 1 HG 15100 LG Enclosure 2 HG DECHLORHG2 HP Dechlorination Chamber 3 HG 123100 2 Composite Control Valve 4 546589 NODE Controller Assembly Programming Option 5 HG S302 BlueTooth Controller Programming Option 6 546767 200 Series Warm High Profile Replacement Piping Assembly 7 HG 15113 P Key Enclosure Security 8 HG S294 HG2 TCV Assembly 1 2...

Page 11: ...11 Notes 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT ...

Page 12: ...ter Products Inc All Rights Reserved The trademarks logos and service marks displayed in this document are the property of Mueller Water Products Inc its affiliates or other third parties Products marked with a section symbol are subject to patents or patent applications For details visit www mwppat com These products are intended for use in potable water applications Please contact your Mueller S...

Reviews: