Muller HYDRO-GUARD 200 Series Operating Instructions Manual Download Page 12

MUELLER

®

 | ECHOLOGICS

®

 | HYDRO GATE

®

 | HYDRO-GUARD

®

 | HYMAX

®

 | JONES

®

 | KRAUSZ

®

 | MI.NET

®

 | MILLIKEN

®

 | PRATT

®

 | SINGER

®

 | U.S. PIPE VALVE AND HYDRANT 

1.800.423.1323 – www.muellerwp.com – [email protected]

INTERNATIONAL

 – 

1.423.490.9555

 – 

www.mueller-international.com

 – 

[email protected]

Mueller refers to one or more of Mueller Water Products, Inc. a Delaware corporation (“MWP”), and its subsidiaries. MWP and each of its  
subsidiaries are legally separate and independent entities when providing products and services. MWP does not provide products or services to  
third parties. MWP and each of its subsidiaries are liable only for their own acts and omissions and not those of each other. MWP brands include Mueller

®

, Echologics

®

, Hydro Gate

®

,  

Hydro-Guard

®

, HYMAX

®

, Jones

®

, Krausz

®

, Mi.Net

®

, Milliken

®

, Pratt

®

, Pratt Industrial

®

, Singer

®

, and U.S. Pipe Valve & Hydrant. Please see muellerwp.com/brands and krauszusa.com to learn more.

© 2021 Mueller Water Products, Inc. All Rights Reserved. The trademarks, logos and service marks displayed in this document are the property  
of Mueller Water Products, Inc., its affiliates or other third parties. Products marked with a section symbol (§) are subject to patents or patent 
applications. For details, visit www.mwppat.com. These products are intended for use in potable water applications. Please contact your  
Mueller Sales or Customer Service Representative concerning any other application(s).

LIMITED WARRANTY 

Thls Hydro-Guard"" Automatic Flushing Device Is warranted for one year from the date of delivery. Mueller Co. will repair or replace any defective part or component as long as the Unit is 
installed and operated In accordance with the procedures descrlbed within this manual. Damage or fallure caused by the Improper installation, assembly, disassembly, maintenance or operation 
of the Hydro-Guard Automatic Flushing Device Is not covered by the terms of this warranty. Call Mueller Co. at 877.864.8500 during regular business hours, or contact HydrowGuard at www.
HydroMGuard,com for detalls on warranty service. 

Summary of Contents for HYDRO-GUARD 200 Series

Page 1: ...elieved 4 Always use all necessary safety equipment and follow all recommended procedures when installing operating and maintaining the Hydro Guard Automatic Flushing Device 5 Replace worn or defective parts with OEM parts and check your battery twice a year 6 Operate the Hydro Guard Automatic Flushing Device only when fully installed and correctly assembled 7 It is recommended that a pressure red...

Page 2: ...Hydro Guard Unit into place pressing it firmly into the noncompacted bedding material until it is fully seated 4 Connect the utility s water system to the Hydro Guard Unit by means of the 2 threaded connection Ensure that Unit is level before beginning the backfilling operation to the installation of the device the drainage patterns for the intended installation location should be reviewed The dra...

Page 3: ...nch the application on your Smartphone or Tablet 4 Associate the controller with your phone by tapping the Add a Controller button 5 The app will now ask what type of Bluetooth device you would like to add 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT Programming Unit PROGRAMMING HYDRO GUARD UNIT FOR OPERATION Discharged water flushed from the Hydro Guard Unit must be routed away from...

Page 4: ...ray and connect the battery connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring a proper seal is created Also The NODE has non volatile memory which allows battery replacement without losing program information Idle Mode Waking Up Normall...

Page 5: ...lush for a different program if desired 5 Press RETURN ENTER key to proceed to next programming function or allow controller to return to Idle mode Manual Flushing Manual flushing allows user to test the Hydro Guard unit or a program for a specified run time Make sure controller is in Idle Mode 1 Press and hold RIGHT ARROW until HAND icon is displayed The station number always 1 will be displayed ...

Page 6: ... Warm Climate Direct Discharge Unit The following is a brief overview and introduction to Hydro Guard Options Sample Station Included A standard feature on the 200 Series Warm Climate High Profile Direct Discharge Unit is the sample port which allows Hydro Guard s Portable Sample Valve Part HG S 1167 to attach to the sample port to obtain a sample Slip off the sanitary blue cap attach the quick co...

Page 7: ...allow for required service and maintenance If disassembly is necessary please follow the directions below Always close the curb stop before working on the unit 200 Series Warm Climate Removal of Internal Compo nents FOR AIR GAP MODEL 1 Shut off water supply and secure isolation valve 2 Remove the housing cover by tilting the housing upward while lifting slightly on its end Once the retaining pin l...

Page 8: ...enoid will not close Try this Correction Run a manual flush for 1 minute Change batteries Check connections for corrosion breaks or lack of connection Check the adapters and solenoid for debris Run the electrical systems check Refer to valve troubleshooting for possible corrective measures Check the water pressure at the unit The pressure must be in the operating range of the solenoid and programm...

Page 9: ...Gap 6 Receiver Pipe By Others Dechlorination System BlueTooth or NODE Controller Integrated Program Mueller Curb Box Optional Mueller 2 Curb Stop Optional Quick Disconnect Supply Line By Others Quick Connect HG S116B Portable Sample Valve Optional SCH 80 PVC Internal Piping Brass Optional 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT ...

Page 10: ...ipe Release Light Green Enclosure ID PART NUMBER DESCRIPTION 1 HG 15100 LG Enclosure 2 HG DECHLORHG2 HP Dechlorination Chamber 3 HG 123100 2 Composite Control Valve 4 546589 NODE Controller Assembly Programming Option 5 HG S302 BlueTooth Controller Programming Option 6 546767 200 Series Warm High Profile Replacement Piping Assembly 7 HG 15113 P Key Enclosure Security 8 HG S294 HG2 TCV Assembly 1 2...

Page 11: ...11 Notes 200 SERIES WARM CLIMATE HIGH PROFILE DIRECT DISCHARGE UNIT ...

Page 12: ...ter Products Inc All Rights Reserved The trademarks logos and service marks displayed in this document are the property of Mueller Water Products Inc its affiliates or other third parties Products marked with a section symbol are subject to patents or patent applications For details visit www mwppat com These products are intended for use in potable water applications Please contact your Mueller S...