6
Operating job computer on the field
Tank filling
34
V1.20180921
30303187-02-EN
1.
Switch to the “Filling - TANK-Control” screen:
2.
- Start filling.
⇨
During the filling procedure, the following icon appears on the screen:
⇨
While filling is taking place, the filled quantity appears on the “Filling - TANK-Control” screen
on the “Current content ” line.
3.
- When the tank is full, switch off pump.
Filling up the tank with TANK-Control and fill stop
If a TANK-Control with fill stop has been installed and configured on the field sprayer, you can use it.
It will stop tank filling automatically when a specified fill level is reached.
You can define up to two refill limits for tank filling. The system stops filling the tank when the tank
content reaches these refill limits.
Function icon
Function
Results
Open ball valve for tank filling
- Ball valve opens.
- The following icon appears on the screen:
- Water is being pumped.
- Current tank content changes slowly.
Close ball valve for tank filling
- Ball valve closes.
Change active refill limit
Only the refill limit selected is taken into
account while filling the tank. The tank is
filled until the fill level is reached.
To fill the tank with two refilling limits:
TANK-Control with fill stop is installed on the field sprayer.
1.
Switch to the “Filling - TANK-Control” screen:
Procedure
6.1.3
Procedure